6. INSTALLATION

Step 1. Secure the ceiling bracket to the ceiling

with 4 screws.
Pull both the lead-in and lead-out cables
through the cable hole in the bracket.

Ceiling bracket (accessory)

Ceiling

Lead-in and lead-out cables

Tapping screw 4 x 16 (accessory)

Note
If these screws are not appropriate
for the ceiling material, separately
prepare the proper screws.

The input power (impedance) is factory-preset to 6 W
(1.7 kΩ) for 100 V line and 3 W (1.7 kΩ) for 70 V line.
When changing this setting, use a standard screwdriver
to rotate the rotary switch on the upper side of the
speaker to the desired position

The input power (impedance) is factory-preset to 30 W
(330 Ω) for 100 V line.
When changing this setting, use a standard screwdriver
to rotate the rotary switches on the upper side of the
speaker to the desired position.

(1) When operating at high impedance (100 V and 70 V lines);

Set the rotary switch of "LINE VOL." to "100 V" or "70 V" and that of "INPUT" to the input power to be used.

(2) When operating at low impedance;

Set both rotary switches of "LINE VOL" and "INPUT" to 8 Ω.

Important

Be sure to follow the instructions below. Failure to do so may cause damage to the speaker.
• Switch off the amplifier's power when changing the input power.
• Never make 8 Ω connection in a 100 V or 70 V line system, as excessive input power is applied to the speaker,

possibly resulting in damage. (PE-304 only)

5. INPUT POWER (IMPEDANCE) CHANGE

Note
Shown above is an example when the input power is
set to 3 W on 100 V line and 1.5 W on 70 V line.

Note
Shown above is an example when the input power is
set to 20 W on 100 V line.

5.2. PE-304

5.1. PE-64

Impedance

1.7 kΩ 3.3 kΩ 10 kΩ

100 V line

6 W

3 W

1 W

70 V line

3 W

1.5 W

0.5 W

Input power

30 W

20 W

15 W

10 W

5 W

100 V line

330 Ω

500 Ω

670 Ω

1 kΩ

2 kΩ

70 V line

170 Ω

250 Ω

330 Ω

500 Ω

1 kΩ

4. WIRING DIAGRAMS

4.1. PE-64

Rotary switch

10 kΩ

OFF

OFF

OFF

3.3 kΩ

1.7 kΩ

8 Ω

0

COM

COM

HOT

Matching
transformer

(Factory-preset wiring)

4.2. PE-304

Rotary switch 2

Network

Rotary switch 1

2 kΩ

1 kΩ

670 Ω

500 Ω

330 Ω

16 Ω

0

8 Ω

0

COM

8 Ω

8 Ω

0

8 Ω

OFF

OFF

70 V

OFF

100 V

SP1

SP2

COM

HOT

Matching
transformer

(Factory-preset wiring)