Toa HY-TB1 User Manual
Tile bar bridge hy-tb1, Warning, Caution
1. SAFETY PRECAUTIONS
• Be sure to read the instructions in this section carefully before use.
• Make sure to observe the instructions in this manual as the conventions of safety symbols
and messages regarded as very important precautions are included.
• We also recommend you keep this instruction manual handy for future reference.
INSTALLATION MANUAL
TILE BAR BRIDGE
HY-TB1
Please follow the instructions in this manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.
Indicates a potentially hazardous situation which, if
mishandled, could result in death or serious personal injury.
WARNING
Indicates a potentially hazardous situation which, if
mishandled, could result in moderate or minor personal
injury, and/or property damage.
CAUTION
• Leave the installation to your TOA dealer because the installation requires expert
knowledge. Improper installation may cause the speaker to fall, resulting in personal injury
and/or property damage.
• Install the mounting hardware in a location that can structurally support the weight of the
mounting hardware and the speaker. Doing otherwise may result in the speaker falling down
and causing personal injury and/or property damage.
• Do not use other methods than specified to mount the unit. Extreme force is applied to the
unit and the unit could fall off, possibly resulting in personal injuries.
• Tighten each screw securely. Ensure that the unit has no loose joints after installation to
prevent accidents that could result in personal injury.
• Use the specified speaker in combination. Doing otherwise may cause the speaker or
component to fall off, resulting in personal injury.
• Avoid touching the unit's sharp metal edge to prevent injury.
2. GENERAL DESCRIPTION
TOA's HY-TB1 Tile Bar Bridge is a 603 mm (23
47
/
64
") long support frame (set of 2 rails)
designed to provide secure support for flush-mounted ceiling speakers while preventing the
speaker's weight from being directly applied to the ceiling panels. Its support rails are
designed to act as mounts for the ceiling reinforcement ring supplied with each speaker.
Before installation, a qualified architect or engineer should first determine whether the ceiling
frames and panels are strong enough to withstand the added weight of ceiling speakers.
Refer to the speaker's instruction manual for information.
[Completed installation figure]
• For Dry Wall Ceilings
Ceiling panel
Reinforcement ring mounting screw
Ceiling reinforcement ring (supplied with speaker)
Ceiling frame
max. 32 mm*
Tie-plate mounting screw
Tie-plate
(preinstalled on Bridge rail)
* This length can be extended to up to 58 mm by turning the tie-plate upside down.
HY-TB1
(optional)
Bridge rail
Ceiling tile
T-grid
Ceiling reinforcement ring (supplied with speaker)
Reinforcement ring mounting screw
Tie-plate mounting screw
Tie-plate
(preinstalled on Bridge rail)
HY-TB1
(optional)
Bridge rail
• For Drop Ceilings
3. SPECIFICATIONS
4. INSTALLATION
Note: The design and specifications are subject to change without notice for improvement.
Finish
Steel plate, plating
Weight
500 g (2 pieces)
Usable Speaker
F-122C, F-122CU, F-2322C, F-2352C, F-2852C