Wiring diagram, Dimensional diagram – Toa PE-154BS User Manual
Page 4
[Top]
[Bottom]
[Front]
ш186 (ш7.32)
PG13.5-12
Cable gland
ш20.3 (ш0.8)
knockout
ш120 (ш4.72)
251 (9.88)
Max. 3000
116
(9.84 ft)
(4.57)
4-ш4.5 (ш0.18)
4-6.6 x 3.6 (0.26 x 0.14)
4.2
(0.17)
42.4
(1.67)
50.9 (2)
65 (2.56)
12
(0.47)
25.45
(1.0)
97 (3.82)
33.9
(1.33)
7.7 (0.3)
42.4
(1.67)
50.9 (2)
9.3 (0.37)
Cable (from
the amplifier)
Cable (to the next speaker)
Cable gland (option)
HOT
COM
Screw terminal
Note: Connect 2 cables.
4
Rotary switch
2 kΩ
OFF
OFF
OFF
1 kΩ
670 Ω
8 Ω
0
COM
COM
HOT
( )
EARTH
Matching
transformer
Network
circuit
(Factory-preset wiring)
Thermal fuse
(84°C or 183.2°F)
Terminal block
COM
HOT
( )
EARTH
SP1
SP2
6. WIRING DIAGRAM
Knockout
Ceiling bracket
Cable gland
5. DIMENSIONAL DIAGRAM
Unit: mm (in)
[When making a bridge connection]
Punch out the knockout in the ceiling bracket and attach
the cable gland (option) there.
Notes
• To punch out the knockout, apply a force to it in the
direction of the arrow as shown at right. In this case,
take care not to bend the metal rim along the knockout.
• Run the cable (to the next speaker) through the cable
gland, then connect the cable to each terminal according
to the polarity indication at the screw terminal.
• Make 2 clearance holes for the cable glands in
the ceiling panel as needed so that the ceiling
bracket can be attached firmly to the ceiling.
ø31
(1.
22)
36 (1.42)
36 (1.42)
12
(0.47)
4-unthreaded hole
[Cable gland hole dimensions (Reference)]
Unit: mm (in)
15 (0.59)
16
(0.63)