beautypg.com

Wiring diagram, Dimensional diagram – Toa PE-154BS User Manual

Page 4

background image

[Top]

[Bottom]

[Front]

ш186 (ш7.32)

PG13.5-12

Cable gland

ш20.3 (ш0.8)

knockout

ш120 (ш4.72)

251 (9.88)

Max. 3000

116

(9.84 ft)

(4.57)

4-ш4.5 (ш0.18)

4-6.6 x 3.6 (0.26 x 0.14)

4.2

(0.17)

42.4

(1.67)

50.9 (2)

65 (2.56)

12

(0.47)

25.45

(1.0)

97 (3.82)

33.9

(1.33)

7.7 (0.3)

42.4

(1.67)

50.9 (2)

9.3 (0.37)

Cable (from
the amplifier)

Cable (to the next speaker)

Cable gland (option)

HOT

COM

Screw terminal

Note: Connect 2 cables.

4

Rotary switch

2 kΩ

OFF

OFF

OFF

1 kΩ

670 Ω

8 Ω

0

COM

COM

HOT

( )

EARTH

Matching
transformer

Network
circuit

(Factory-preset wiring)

Thermal fuse
(84°C or 183.2°F)

Terminal block

COM

HOT

( )

EARTH

SP1

SP2

6. WIRING DIAGRAM

Knockout

Ceiling bracket

Cable gland

5. DIMENSIONAL DIAGRAM

Unit: mm (in)

[When making a bridge connection]

Punch out the knockout in the ceiling bracket and attach
the cable gland (option) there.

Notes
• To punch out the knockout, apply a force to it in the

direction of the arrow as shown at right. In this case,
take care not to bend the metal rim along the knockout.

• Run the cable (to the next speaker) through the cable

gland, then connect the cable to each terminal according
to the polarity indication at the screw terminal.

• Make 2 clearance holes for the cable glands in

the ceiling panel as needed so that the ceiling
bracket can be attached firmly to the ceiling.

ø31

(1.

22)

36 (1.42)

36 (1.42)

12

(0.47)

4-unthreaded hole

[Cable gland hole dimensions (Reference)]

Unit: mm (in)

15 (0.59)

16

(0.63)