8. RACK MOUNTING
Notes
• Install the unit in locations where the temperature is between 0 and +40°C and the moisture is less than 90%
(no dew condensation must be formed).
• When mounting the DP-L2 in an equipment rack, ensure good ventilation by removing all of the panels
located on the rear of the rack. Also, be sure to mount a perforated panel larger than 1U size at the top and
bottom of the rack.
• When mounting two DP-L2 units in an equipment rack, be sure also to mount a perforated panel larger than
1U size above and below the two units, as shown in the figure.
• When rack-mounting the DP-L2 close to a power amplifier or other heat-generating equipment, be sure to
mount the unit below the equipment so that it is not affected by the rising heat.
Power amplifier
Perforated panel
Equipment rack
DP-L2
DP-L2
Rack-mounting screw
Note
As no rack-mounting screws are supplied,
prepare locally the screws appropriate for the rack.
When installing the unit in an equipment rack, do not to block the ventilation slots on the unit's sides
and rear.
Doing so may cause heat to build up inside the unit and result in fire.
CAUTION
Lors de l'installation de l'appareil en bâti, veiller à ne pas obstruer les évents de ventilation sur les
côtés et l'arrière sous peine de provoquer une accumulation de chaleur à l'intérieur de l'appareil,
pouvant aboutir à un incendie.
ATTENTION