beautypg.com

Toa DP-L2 v.2.00 User Manual

Page 20

background image

20

A D J . Z E R O

S : + 1 0

0 d B

L :

– 3

11
10

9
8
7
6
5
4
3
2
1
0

0

dB

–3

–6

–9

–12

80 dB

68 dB

Noise range in which you desire
to control the output level.

Ambient noise level

SENSOR level

SENSOR level

Output level

Output level

ZERO level set by following MIN NOISE SET
instruction (Step 4-1)

ZERO level correction value

Current noise level (A)

Adjusted output level

A D J . Z E R O

S :

0

+ 1 0 d B

L : – 1 2

11
10

9
8
7
6
5
4
3
2
1
0

0

dB

–3

–6

–9

–12

80 dB

68 dB

+10 dB

Noise range in which you desire
to control the output level.

Ambient noise level

SENSOR level

SENSOR level

Output level

Output level

ZERO level set by following MIN NOISE SET
instruction (Step 4-1)

ZERO level correction value

Current noise level (A)

Adjusted output level

Correct the ZERO level to this position.

Increase

[When the preset minimum ambient noise level is extremely lower than the actual level]
In this case, the unit recognizes that the ambient noise is high even in low ambient noise condition (A) where
the unit is actually used, providing sound output at high level (–3 dB in this example).

Correct the ZERO level to a higher level to obtain the optimum operation according to the cases (1) and (2)
below.

(1) If the current noise level (A) is the minimum ambient noise level when the unit is actually used, increase

the ZERO level so that the SENSOR level (S) becomes "0."