Toa FS-971 SERIES User Manual
Page 32

32
7.6.7. Notes on input level settings when increasing the output
When increasing output numbers to 8, 12 or 16 outputs by connecting two or more IM-011s, the inputs
common to each IM-011 unit must be set for the same level. Refer to the following examples.
• Eight outputs
Important: All of the above input levels must have the same setting regardless of increased input numbers.
The figure below shows the inputs of both "Address 0" and "Address 1" panels are set for the same level
when their outputs are increased.
1
2
3
4
Audio input/output expansion (16 inputs/8 outputs configuration)
Note: "Exp" in the figure is short for "expansion".
1
2
3
4
4
3
2
1
4
3
2
1
Exp audio input
Audio input
Audio output
Exp audio output
Address
A
1
2
3
4
4
3
2
1
4
3
2
1
Exp audio input
Audio input
Audio output
Exp audio output
Address
B
1
2
3
4
4
3
2
1
4
3
2
1
Exp audio input
Audio input
Audio output
Exp audio output
Address
8
1
2
3
4
4
3
2
1
4
3
2
1
Exp audio input
Audio input
Audio output
Exp audio output
Address
4
1
2
3
4
4
3
2
1
4
3
2
1
Exp audio input
Audio input
Audio output
Exp audio output
Address
9
1
2
3
4
4
3
2
1
4
3
2
1
Exp audio input
Audio input
Audio output
Exp audio output
Address
5
1
2
3
4
4
3
2
1
4
3
2
1
Exp audio input
Audio input
Audio output
Exp audio output
Address
0
1
2
3
4
4
3
2
1
4
3
2
1
Exp audio input
Audio input
Audio output
Exp audio output
Address
1
0 dB
-20 dB
0 dB
-20 dB
Audio input 2
Audio input 2
To internal circuit
To internal circuit
Expansion audio output 2
Expansion audio output 2
Input level setting switch
Input level setting switch
Address 0
Address 1
Set all inputs 1–4 of both the "address A" and "address B" panels
for the same level.
Set all inputs 1–4 of both the "address 0" and "address 1" panels
for the same level.
Set all inputs 1–4 of both the "address 8" and "address 9" panels
for the same level.
Set all inputs 1–4 of both the "address 4" and "address 5" panels
for the same level.