background image

13

4.3. Priority Setting When Multiple RM-1100s Are Connected

4.3.1. Priority setting

First-in-first-out priority: Connect the First-in-first-out terminal of one remote control unit to the same terminal

of another. Up to five units can be connected for the FIFO priority function.

Remote Control Unit 1

Remote Control Unit 2

ANN ON

RM

1ST-IN-1ST-OUT

R

T

PRIORITY

ALL-ZONE

CHIME

COM

+

-

24 VDC

POWER

REMOTE

OUTPUT

H

C

E

ANN ON

RM

1ST-IN-1ST-OUT

R

T

PRIORITY

ALL-ZONE

CHIME

COM

+

-

24 VDC

POWER

REMOTE

OUTPUT

H

C

E

Remote Control Unit 1

Remote Control Unit 2

ANN ON

RM

1ST-IN-1ST-OUT

R

T

PRIORITY

ALL-ZONE

CHIME

COM

+

-

24 VDC

POWER

REMOTE

OUTPUT

H

C

E

ANN ON

RM

1ST-IN-1ST-OUT

R

T

PRIORITY

ALL-ZONE

CHIME

COM

+

-

24 VDC

POWER

REMOTE

OUTPUT

H

C

E

Of the two remote control units, the unit making an announcement first takes
precedence. While one unit is in use, other remote control unit cannot be used.

Individual unit priority: Connect the Individual unit priority/sending [priority/T] terminal of the remote control unit

given higher priority to the Individual unit priority/receiving [priority/R] terminal of the unit
with lower priority. Up to five units can be connected.

4.3.2. When not setting the priority order

When using only one RM-1100 unit or when using multiple units but not assigning priority, do not connect the
First-in-first-out terminal or Individual unit priority terminal.

Note
To play chime from the RM-1100, the Pre-amplifier Panel PP-025B which has an internal chime unit CK-025
must be installed in the main rack.

In this example, Remote Control Unit 1 takes precedence over Remote Control Unit 2.
While Unit 1 is making broadcast, Unit 2 cannot be used. Conversely, while Unit 2 is
making broadcast, Unit 1 can be used.