12

www.teejet.com

FieldPilot

®

J

J

6. install eF Fittings and hose

Locate the priority valve and relief valve underneath the machine near the middle. Disconnect the hose going

into the relief valve from the pump. Install fittings

(Q)

on the fitting on the relief valve and on the EF port of the

FieldPilot Valve. Connect hose

(L)

from the relief valve to the EF port on the FieldPilot Valve. The hose will route

along the left side of the machine with other hoses.
Figure 1-9: Installing the EF Fittings and Hose

disconnect

priority

Relief

Q