System Setup Mode
The System Setup Mode contains the programming steps that customize the monitor to the
sprayer or sprayer components. These include calibration steps and parameters that, once
programmed, will likely never change.
To enter the System Setup Mode:
☛
First be sure that the console is ON (if not turn it on by pressing the key and wait
until the normal display is visible).
☛
Ensure the Master boom switch is OFF.
☛
Then press and hold the key for 3 seconds to enter the Program Mode.
D
ENSITY
Default = 1.00
If a substance other than water is being sprayed
or used as a carrier (e.g. liquid fertilizer), enter
the density of that fluid.
Weight of
Solution Per Gallon
Liquid
Density
7.0 lbs.
0.84
8.0 lbs.
0.96
8.34 lbs. - Water
1.00
10.0 lbs.
1.20
10.65 lbs. – 28% N
1.28
10.85 lbs. – 30% N
1.30
11.0 lbs.
1.32
12.0 lbs.
1.44
14.0 lbs.
1.68
Use the
+
or
keys to adjust this value. Once the correct units have been selected,
tip spacing
(inch)
speed cal
(pulses/300ft.)
PROGRAM MODE push 3 sec.
density
Tip
select GPA
MPH
PSI
On
1.00
Note: If the solution that you
are using can not be found in
the chart at left, the Liquid
Density can be calculated as
follows:
Density = Weight of Solution
Weight of Water