beautypg.com

SUUNTO COBRA User Guide User Manual

Page 12

background image

WARNING

THE DIVE COMPUTER WILL NOT ACCEPT FRACTIONAL
PERCENTAGE VALUES OF OXYGEN CONCENTRATION. DO
NOT ROUND UP FRACTIONAL PERCENTAGES! For example,
31.8% oxygen should be entered as 31%. Rounding up will cause
nitrogen percentages to be understated and will affect decompres-
sion calculations. If there is a desire to adjust the computer to
provide more conservative calculations, use the personal adjust-
ment feature to affect decompression calculations or reduce the
PO

2

setting to affect oxygen exposure according to the entered

O

2

% and PO

2

values.

WARNING

SET THE CORRECT ALTITUDE ADJUSTMENT MODE! When
diving at altitudes greater than 300 m/1000 ft, the Altitude Adjust-
ment feature must be correctly selected in order for the computer
to calculate the decompression status. The dive computer is not
intended for use at altitudes greater than 3000 m/10000 ft. Failure
to select the correct Altitude Adjustment setting or diving above
the maximum altitude limit will result in erroneous dive and plan-
ning data.

12