Click the Sensor/Show SAS Lane Power vs Time menu item to open the SAS Lane Power vs
Time Plot Display Window (Figure 7). To select each lane for setup:
Click
the
Pause button,
Click
the
Lane Selection option ,
Click
the
Continue button.
After selecting a lane for setup, adjust the lane sensitivity by left clicking in the upper or lower
part of the Lane Sensitivity field (1-Sens, 2-Sens, etc. to the right of the plotting area). This will
cause the
Red Trace (Calculated Detection Threshold)
to move up or down in 0.25 db
increments. Adjust the Lane Sensitivity for each lane until the
Red Trace
is approximately 3 to
5 db above the
Cyan Trace
for the Minimum Sensitivity Threshold (T-Minimum Sensitivity).
The
Red Trace
will track below the
Blue Trace (Avg Peak Value)
by the amount of the Lane
Sensitivity. Typical values for Lane Sensitivity are 4 to 6 db.
Click the Close button to close the SAS Lane Power vs Time Plot Window. On the SAS
Monitor and Setup main display click the Save Par , and the Send Par button.
Calibrate Speed Estimates for Each Lane
Figure 7 Setting Detection Sensitivity for Each Lane