Table 12-1 -

Correspondence table to set

space heating

input

12 - START-UP

“P” parameter

value

Correspondent

heat input

(btu/hr)

12.10 - Adjusting
the heating
capacity

This boiler has been engineered
with an “intelligent” micro-processor
control that will adjust the heating
output to match the system demand.
To maximize the effectiveness of

the system, the parameters

found in the “Installer’s menu”, in
Section 13.17, can be adjusted set
the maximum heating output to the
effective maximum load necessary

for the system. The

parameter

can be adjusted from 100 (factory
set value), to 1. The correspondence

between

value and heating output

is given by table in Figure 12-1.

NOTE: This setting, adjusts the
heating input only. The domestic
output is always 160,000 btu/hr for

every

value.

12.11 - Domestic
hot water fl ow rate
adjustment (160-C
model only)

The volume of domestic hot water
that the boiler can produce, depends
on the fl ow rate of the domestic water
system. If the fl ow rate is too high,
the water will move through the heat
exchanger without being adequately
heated. It is therefore advisable to
carry out the following adjustments:
1. switch the on/off power switch, item

“12” in fi gure 13-1, to “on”;

2. adjust control “11” as shown in

Figure 13-1, to 130 °F (50 °C);

3. fully open a hot water faucet. If a

mixing type faucet with single lever
is opened, the position must be
fully to HOT;

4. set the domestic hot water mixing

valve (fi eld installed), to its
maximum value);

5. wait 5 minutes for the temperature

to stabilize;

6. if the water temperature is too

low, reduce the water fl ow using a
fl ow restrictor (Field installed) until
reaching the desired temperature
(turn the fl ow restrictor in small
increments and wait for the
temperature to stabilize to prevent
overshooting the desired value).

NOTE: Water fl ow should generally
be regulated according to the
values given in Section 15, under
the heading “instantaneous d.h.w.
production [rise 75 °F (42 °C)]
”.

12.12 - Cold start
boiler

The boiler has a “cold start” working
mode. Any time the room thermostat
opens (no call for heat), the burner
stops immediately. However even with
the room thermostat contact open, the
boiler will run for freeze protection as
described in Section 13.14.