beautypg.com

Err 1, Err 2, Err 3 – Culligan Gold Series User Manual

Page 35: Err 4, Check salt

background image

The Accusoft Plus microprocessor is equipped with an advanced error detection system. During all

operating modes the softener’s electronics are performing self-diagnostics to ensure that the unit is

operating correctly. There may be times, however, when something may occur that could cause the

unit to improperly operate. In those instances the microprocessor will identify the exact problem and

alert the user with an error code. Shown below is a description of the error codes.

Display

Alert Code

Description

Mode of Detection

Comments

ERR 1

Motor Failure to Start

If the valve fails to reach

the desired state within

70 seconds of driving the

motor. The control will

attempt to start the motor 3

times for 70 seconds each

time with a 60 second

off period between each

attempt.

Press and hold ‘Program’

key for 10 seconds.

ERR 2

Motor Failure to Stop

If the control detects

changes in the Cam inputs

when the motor is not

supposed to be turning.

Press and hold ‘Program’

key for 10 seconds.

ERR 3

Incorrect Cycle

Position

The control expects to be

in a different position than

that indicated by the Cam

switch closures.

Press and hold ‘Program’

key for 10 seconds.

ERR 4

Control type does not

match.

-If dips# 3 & 4 are set for

‘Gold’ and 4-cycle valve

is detected. -If dips# 3

& 4 are set for ‘Gold’ or

‘Europe’ and 5-cycle valve

is detected.

Press and hold ‘Program’

key for 10 seconds.

CHECK
SALT

A/S mode; control

detected no brine

during brine rinse

cycle.

A very distinct signal is

expected from the probe

during brine rinse; lack of

this signal means no brine

was detected.

Once this alert is triggered,

the A/S is no longer

a valid regen trigger.

The alert can only be

cleared after a successful

regeneration of the resin

bed.

Beeping only occurs between the hours of 8:00 am and 8:00 pm. Beeping can be silenced by

pressing any key.
To reset an error, press and hold for 10 seconds the ‘Program’ button. The unit will beep and check

to see if indeed the error has been fixed. If the error was not fixed, the board will re-display the

error code. If the error code does not reset please contact your local Culligan Dealer. For additional

troubleshooting or service needs, please contact your local Culligan Dealer.

Error Codes

35