Err 1, Err 2, Err 3 – Culligan Gold Series User Manual
Page 35: Err 4, Check salt
The Accusoft Plus microprocessor is equipped with an advanced error detection system. During all
operating modes the softener’s electronics are performing self-diagnostics to ensure that the unit is
operating correctly. There may be times, however, when something may occur that could cause the
unit to improperly operate. In those instances the microprocessor will identify the exact problem and
alert the user with an error code. Shown below is a description of the error codes.
Display
Alert Code
Description
Mode of Detection
Comments
ERR 1
Motor Failure to Start
If the valve fails to reach
the desired state within
70 seconds of driving the
motor. The control will
attempt to start the motor 3
times for 70 seconds each
time with a 60 second
off period between each
attempt.
Press and hold ‘Program’
key for 10 seconds.
ERR 2
Motor Failure to Stop
If the control detects
changes in the Cam inputs
when the motor is not
supposed to be turning.
Press and hold ‘Program’
key for 10 seconds.
ERR 3
Incorrect Cycle
Position
The control expects to be
in a different position than
that indicated by the Cam
switch closures.
Press and hold ‘Program’
key for 10 seconds.
ERR 4
Control type does not
match.
-If dips# 3 & 4 are set for
‘Gold’ and 4-cycle valve
is detected. -If dips# 3
& 4 are set for ‘Gold’ or
‘Europe’ and 5-cycle valve
is detected.
Press and hold ‘Program’
key for 10 seconds.
CHECK
SALT
A/S mode; control
detected no brine
during brine rinse
cycle.
A very distinct signal is
expected from the probe
during brine rinse; lack of
this signal means no brine
was detected.
Once this alert is triggered,
the A/S is no longer
a valid regen trigger.
The alert can only be
cleared after a successful
regeneration of the resin
bed.
Beeping only occurs between the hours of 8:00 am and 8:00 pm. Beeping can be silenced by
pressing any key.
To reset an error, press and hold for 10 seconds the ‘Program’ button. The unit will beep and check
to see if indeed the error has been fixed. If the error was not fixed, the board will re-display the
error code. If the error code does not reset please contact your local Culligan Dealer. For additional
troubleshooting or service needs, please contact your local Culligan Dealer.
Error Codes