Connect the Brine Line
• Measure a length of brine line sufficient to
reach from the brine tank to the brine fitting,
with no sharp bends. For easier access to the
float it is recommended to add an extra four
feet (1.3 meters) of length to the brine line.
Cut both ends of the brine line squarely and
cleanly.
• Slip the white nut over one end of the tubing
and press the plastic insert into the end of the
tubing (Figure 11). Connect to the brine valve
and tighten nut.
• Remove white nut and plastic insert from the small parts pack.
• Slip the white nut over one end of the tubing and press the plastic insert into the end of the
tubing (Figure 11). Connect to the brine connection on the valve and tighten nut.
Electrical Connection
The power cord needs to be connected to the plug-in transformer. Figure 19 shows the cord
attachment to the transformer for non Aqua-Sensor models.
The Aqua-Sensor probe (Figure 12) requires a 2.5 VAC power source. This source is provided via
two of the posts on the 24V/2.5V transformer. Two leads from the transformer must be wired to the
2.5 VAC terminal on the circuit board. The wire connector from the Aqua-Sensor probe is simply
plugged in the circuit board (Figure 13).
19
Note: Observe all state and local electrical codes.
Figure 12
Figure 11
Caution! Failure to connect power to the correct terminals will damage the circuit board!
Figure 13
2.5VAC
Aqua-Sensor
Power
24VAC
Power
White
Red
Black
Blue or Green
Aqua-Sensor Wiring