Rating plate 2, Serial no. 2, Reznor – Reznor SDH Parts Manuals User Manual
Page 2: Serial no. and rating plate, Sample of optional reheat rating plate, Serial no. date of manufacture codes (all models), A = ansi standard date a

Form P-PREEVA, P/N 263985R7, Page 2
Serial No. Date of Manufacture Codes (all Models)
Sample of Gas-Fired Model Heat
Section Rating Plate and Key
A = ANSI Standard Date
A
1
= CSA Standard Date
B = Model No.
C = Date of Manufacture (Month/Year)
D = Blower Motor HP (Option)
E = Input Amps
F = Fuel Type (natural gas or propane)
G = Normal Manifold Pressure
Year
Jan
Feb
Mar
Apr
May
June
July
Aug
Sept
Oct
Nov
Dec
2005
BEA
BEB
BEC
BED
BEE
BEF
BEG
BEH
BEI
BEJ
BEK
BEL
2006
BFA
BFB
BFC
BFD
BFE
BFF
BFG
BFH
BFI
BFJ
BFK
BFL
2007
BGA
BGB
BGC
BGD
BGE
BGF
BGG
BGH
BGI
BGJ
BGK
BGL
2008
BHA
BHB
BHC
BHD
BHE
BHF
BHG
BHH
BHI
BHJ
BHK
BHL
2009
BIA
BIB
BIC
BID
BIE
BIF
BIG
BIH
BII
BIJ
BIK
BIL
2010
BJA
BJB
BJC
BJD
BJE
BJF
BJG
BJH
BJI
BJJ
BJK
BJL
2011
BKA
BKB
BKC
BKD
BKE
BKF
BKG
BKH
BKI
BKJ
BKK
BKL
2012
BLA
BLB
BLC
BLD
BLE
BLF
BLG
BLH
BLI
BLJ
BLK
BLL
2013
BMA
BMB
BMC
BMD
BME
BMF
BMG
BMH
BMI
BMJ
BMK
BML
2014
BNA
BNB
BNC
BND
BNE
BNF
BNG
BNH
BNI
BNJ
BNK
BNL
2015
BOA
BOB
BOC
BOD
BOE
BOF
BOG
BOH
BOI
BOJ
BOK
BOL
2016
BPA
BPB
BPC
BPD
BPE
BPF
BPG
BPH
BPI
BPJ
BPK
BPL
2017
BQA
BQB
BQC
BQD
BQE
BQF
BQG
BQH
BQI
BQJ
BQK
BQL
2018
BRA
BRB
BRC
BRD
BRE
BRF
BRG
BRH
BRI
BRJ
BRK
BRL
2019
BSA
BSB
BSC
BSD
BSE
BSF
BSG
BSH
BSI
BSJ
BSK
BSL
2020
BTA
BTB
BTC
BTD
BTE
BTF
BTG
BTH
BTI
BTJ
BTK
BTL
Serial No. and Rating Plate
Serial No. Decoding - Gas-Fired Models
Serial No. Sample:
BHD 78 Y8 N 00000
Element Key No.:
1 | 2 | 3 |4| 5
Key: 1 = Date of Manufacture (See table right.)
2 = Ignition Code (See Form P-Valves to identify by
code.)
3 = Valve Code (See Form P-Valves to identify by code.)
4 = Type of Heat Energy (N = Natural Gas; L = Propane)
5 = Consecutive number
REZNOR
®
MERCER, PA. USA 16137
SEPARATED COMBUSTION SYSTEM UNIT HEATER
FOR INDUSTRIAL/COMMERCIAL USE
CATEGORY [ S ]
ANSI Z83.8 [
A ] CSA 2.6 [ A’ ] UNIT HEATER
MODEL [ B ] [ C ]
SERIAL NO. [ D ] HP
[ E ] VOLTS [ E ] PH [ E ] HZ MAXIMUM TOTAL INPUT [ E ] AMPS
TYPE OF GAS: [ F ]
FOR USE AT
[ I ] FEET, [ I’ ] METERS OF ALTITUDE.
ORIFICE SIZE [
L ] DRILL
SEA LEVEL ALT. ADJUSTED
NORMAL INPUT
[
N ] [ X ] BTU/HR
THERMAL OUTPUT CAPACITY
[
P ] [ Y ] BTU/HR
MINIMUM INPUT (2,2L,D2,DM,D2J,DMJ MODELS) [
Q ] [ Z ] BTU/HR
NORMAL MANIFOLD PRESSURE
[
G ] [ AA ] IN. W.C.
MIN. PERMISSIBLE GAS SUPPLY PRESSURE
FOR PURPOSE OF INPUT ADJUSTMENT.
[
H ] IN.
TEMPERATURE RISE RANGE FROM
[ J ] DEG. F. TO [ K ] DEG. F.
MAXIMUM EXTERNAL STATIC PRESSURE
[ M ] IN. W.C.
EQUIPPED FOR OPERATION AT AN AIR FLOW OF
[ T ] SCFM
AGAINST A STATIC PRESSURE OF
[ U ] IN. W.C.
DRIVE NO.
[ V ]
WIRING DIAGRAM
[ W ]
CLEARANCES TO COMBUSTIBLE CONSTRUCTION: TOP-18”, FLUE
CONNECTION-18”, CONTROL SIDE-
[ R ]”, OPP. SIDE-18”, BOTTOM-0”, FRONT-48”
FOR ALTERNATE INSTALLATIONS USE THE LATEST EDITIONS OF THE
APPROPRIATE STANDARD LISTED BELOW:
FOR AIRCRAFT HANGARS
USE STANDARD ANSI/NFPA 409
FOR PARKING STRUCTURES
USE STANDARD ANSI/NFPA 88A
FOR REPAIR GARAGES
USE STANDARD ANSI/NFPA 88B
INSTALLATION OF THIS UNIT IN AIRCRAFT HANGERS IN ACCORDANCE WITH THE
REQUIREMENTS OF THE ENFORCING AUTHORITIES AND IN PUBLIC GARAGES IN
ACCORDANCE WITH THE CAN/CSA-B149 CODES.
THIS UNIT MAY BE INSTALLED DOWNSTREAM FROM A REFRIGERATION SYSTEM.
THIS UNIT MAY BE USED WITH DUCTS AND FILTERS.
CONSTRUCTION WALL THICKNESS FOR PURPOSE OF VENTING: 1” MIN., 48” MAX.
Prefix to Gas-Fired Model Serial No.
Prefix Key: E = E3 (409) Stainless Steel Heat Exchanger
S = 316 Stainless Steel Heat Exchanger
Serial No. Decoding - Electric Heat Models
Serial No. Sample:
BHD D12D E 00000
Element Key No.:
1 | 2 |3| 4
Key: 1 = Date of Manufacture (See table right.)
2 = Ignition Code (D12D, D12E, EG1M, EG2M)
3 = Type of Heat Energy (E = Electric)
4 = Consecutive number
REZNOR
®
MERCER, PA. USA 16137
MADE IN USA
UNIT HEATER FOR INDUSTRIAL/COMMERCIAL USE
MODEL [ A ] [ B ]
SERIAL NO.
[ C ] VOLTS +/- 10% [ C ] PH [ C ] HZ
MINIMUM CIRCUIT AMPACITY (MCA)
[ D ] AMPS
MAXIMUM FUSE SIZE/*CKT BREAKER
[ E ] AMPS
*HACR TYPE REQUIRED PER NEC
NORMAL INPUT
[ F ] KW
QTY
FLA
HP
SUPPLY AIR BLOWER MOTOR
1
[ G ]
[ H ]
TEMPERATURE RISE RANGE FROM 20 DEG. F. TO 75 DEG. F.
MAXIMUM EXTERNAL STATIC PRESSURE 3.0 IN. W.C.
EQUIPPED FOR OPERATION AT AN AIR FLOW OF
[ I ] SCFM
AGAINST A STATIC PRESSURE OF
[ J ] IN. W.C.
DRIVE NO.
[ K ]
WIRING DIAGRAM
[ L ]
CLEARANCES TO COMBUSTIBLE CONSTRUCTION: TOP-6",
CONTROL SIDE-20", OPP. SIDE-6", BOTTOM-0"
QTY
RLA (EA) LRA
COMPRESSOR
1
[ N ]
[ O ]
REFRIGERANT -
R-410A CHARGE - [ P ] LBS
TEST PRESSURES - HIGH 600 PSIG, LOW 112 PSIG
Sample of Electric Model Rating
Plate with Optional Reheat
A = Model No.
B = Date of Manufacture (Month/Year)
C = Supply Voltage
D = MCA
E = Maximum Fuse Size
F = KW
G = Blower Motor FLA
H = Blower Motor HP
I = SCFM
J = Static Pressure
K = Drive Option Designation (AM__)
L = Wiring Diagram No.
N = AU7 Compressor RLA
O = AU7 Compressor LRA
P = Compressor Refrigerant Charge
REZNOR
®
MERCER, PA., U.S.A. 16137
MADE IN USA
UNIT HEATER FOR INDUSTRIAL/COMMERCIAL USE
MODEL [ B ]
SERIAL NO. [ ]
ELECTRICAL
[ E ] VOLTS +/- 10% [ E ] PHASE [ E ] HZ
MINIMUM CIRCUIT AMPACITY (MCA)
[ AH ] AMPS
MAXIMUM FUSE SIZE/*CKT BREAKER
[ AI ] AMPS
FUSIBLE MAX./DISJONCTEUR MAX.
[ AI ] AMPS
QTY
FLA (EA)
HP (EA)
SUPPLY AIR BLOWER MOTOR
1
[ AJ ]
[ D ]
QTY
RLA (EA) LRA (EA)
COMPRESSOR A
[ AD ]
[ AE ]
[ AF ]
CIRCUITS
A
REFRIGERANT -
R-410a CHARGE - LBS
[ AG ]
TEST PRESSURES
HIGH
600PSIG
LOW
112PSIG
REFER TO RATING PLATE IN THE FURNACE SECTION (WHEN USED)
FOR ADDITIONAL INFORMATION.
*HACR TYPE REQUIRED PER NEC
H = Minimum Gas Supply Pressure
I = Altitude (Feet)
I
1
= Altitude (Meters)
J = Minimum Temperature Rise (°F)
K = Maximum Temperature Rise (°F)
L = Orifice Size
M = Maximum External Static
N = Normal BTUH Input (sea level)
P = Thermal Output BTUH (sea level)
Q = Minimum BTUH Input (sea level)
R = Control Side Clearance (inches)
S = Category
T = SCFM
U = Static Pressure
V = Drive Option Designation (AM__)
W = Wiring Diagram No.
X = Normal BTUH Input (adjusted for altitude)
Y = Thermal Output BTUH (adjusted for altitude)
Z = Minimum BTUH Input (adjusted for altitude)
AA = Normal Manifold Pressure (inches w.c.
adjusted for altitude)
Sample of Optional Reheat Rating
Plate
B = Model No.
D = Blower Motor HP (Option)
E = Input Amps
AD = Compressor Quantity
AE = Compressor RLA
AF = Compressor LRA
AG = Compressor Refrigerant Charge
AH = MCA
AI = Maximum Fuse Size
AJ = Blower Motor FLA
Serial No. Decoding - Air Handler Models
Serial No. Sample:
BHD D12D E 00000
Element Key No.:
1 | 2 |3| 4
Key: 1 = Date of Manufacture (See table right.)
2 = Consecutive number