Rating plate 2, Serial no 2, Rating plate and serial no. rating plate key – Reznor MASA Parts Manuals User Manual
Page 2: Serial no, Reznor

P-COND (11-14), P/N 268631R2, Page 2
Rating Plate and
Serial No.
Rating Plate Key
A = Model MASA 060, 090, 120, 150, 180,
240
B = Manufacturing Date
C = BTU
D = Volts (208/230; 480; 575),
3 Phase, 60 Hz
F = Minimum Circuit Ampacity
G = Maximum Fuse Amps
H = 1 Circuit A Compressor
I = Circuit A Compressor Rated Load (Amps)
J = Circuit A Compressor Locked Rotor
(Amps)
K = 1 Circuit B Compressor
L = Circuit B Compressor Rated Load Amps
M = Circuit B Compressor Locked Rotor
Amps
T = Condenser Fan Quantity (1 or 2)
U = Condenser Fan Load (Amps)
Z = Condenser Fan Motor HP (.75)
AA = Wiring Diagram No.
Serial No.
The serial number consists of an alpha date Code, a numeric date Code, and a consecutive
number.
Serial No. Example: BGJ400705394
BGJ = Date Code from table below
4007 = 40th week of the year 2007
05394 = Consecutive number
Year
Jan
Feb
Mar
Apr
May
June
July
Aug
Sept
Oct
Nov
Dec
2006
BFA
BFB
BFC
BFD
BFE
BFF
BFG
BFH
BFI
BFJ
BFK
BFL
2007
BGA
BGB
BGC
BGD
BGE
BGF
BGG
BGH
BGI
BGJ
BGK
BGL
2008
BHA
BHB
BHC
BHD
BHE
BHF
BHG
BHH
BHI
BHJ
BHK
BHL
2009
BIA
BIB
BIC
BID
BIE
BIF
BIG
BIH
BII
BIJ
BIK
BIL
2010
BJA
BJB
BJC
BJD
BJE
BJF
BJG
BJH
BJI
BJJ
BJK
BJL
2011
BKA
BKB
BKC
BKD
BKE
BKF
BKG
BKH
BKI
BKJ
BKK
BKL
2012
BLA
BLB
BLC
BLD
BLE
BLF
BLG
BLH
BLI
BLJ
BLK
BLL
2013
BMA
BMB
BMC
BMD
BME
BMF
BMG
BMH
BMI
BMJ
BMK
BML
2014
BNA
BNB
BNC
BND
BNE
BNF
BNG
BNH
BNI
BNJ
BNK
BNL
2015
BOA
BOB
BOC
BOD
BOE
BOF
BOG
BOH
BOI
BOJ
BOK
BOL
2016
BPA
BPB
BPC
BPD
BPE
BPF
BPG
BPH
BPI
BPJ
BPK
BPL
2017
BQA
BQB
BQC
BQD
BQE
BQF
BQG
BQH
BQI
BQJ
BQK
BQL
2018
BRA
BRB
BRC
BRD
BRE
BRF
BRG
BRH
BRI
BRJ
BRK
BRL
2019
BSA
BSB
BSC
BSD
BSE
BSF
BSG
BSH
BSI
BSJ
BSK
BSL
2020
BTA
BTB
BTC
BTD
BTE
BTF
BTG
BTH
BTI
BTJ
BTK
BTL
Month and Year Date
Code Table for Decoding
Serial No.
REZNOR
MERCER, PA. USA 16137
MADE IN USA
FOR INDUSTRIAL/COMMERCIAL USE ONLY
FOR OUTDOOR USE
MODEL [ A ]
[ B ]
[ C ]
BTU
SERIAL NO. [ ]
[ D ] VOLTS +/- 10%
[ D ] PH
[ D ] HZ
MINIMUM CIRCUIT AMPACITY (MCA)
[ F ] AMPS
MAXIMUM FUSE SIZE/*CIRCUIT BREAKER (MOP) [ G ] AMPS
SHORT-CIRCUIT CURRENT: 5,000 RMS SYMMETRICAL, [D] V MAXIMUM
QTY
FLA (EACH) HP (EACH)
CONDENSER FAN MOTOR (S)
[ T ]
[ U ]
[ Z ]
QTY
RLA (EA)
LRA (EA)
COMPRESSOR A (1st STAGE)
[ H ]
[ I ]
[ J ]
COMPRESSOR B (2nd STAGE)
[ K ]
[ L ]
[ M ]
MINIMUM R-410A DESIGN PRESSURE IS 45 PSI
MAXIMUM R-410A DESIGN PRESSURE IS 600 PSI
WIRE DIAGRAM [ AA ]
*HACR TYPE REQUIRED PER NEC