Date of manufacturer 2, Rating plate 2, Serial no. 2 – Reznor LDAP Parts Manuals User Manual
Page 2: Rating plate and serial no, Example of a model ldap rating plate, Decoding a serial no, References

Form P-LDAP, P/N 271892R1, page 2
Rating Plate and Serial No.
Example of a Model LDAP Rating Plate
First Element of the
Serial Number - Date of
Manufacturer
Rating Plate Key
Decoding a Serial No.
Example of a Serial No. BDF 79 X7 N 00000
Code Nos.
1 2 3 4 5
Code No. Explanation
1
Date of manufacture (see table below)
2
Type of ignition system
3
Type of gas valve
4
Gas (N = natural; L = propane)
5
Consecutive number (identification only)
REZNOR
®
MERCER, PA. USA 16137
MADE IN MEXICO
UNIT HEATER
CATEGORY III
ANSI Z83.8
[AA] [ A ] CSA 2.6 [AA’] [ A’ ] UNIT HEATER
MODEL [ B ] [ C ]
SERIAL NO.
[ D ] VOLTS [ D ] PH [ D ] HZ MAXIMUM TOTAL INPUT [ D ] AMPS
TYPE OF GAS: [ E ]
FOR USE AT 0-2000 FEET, 0-610 METERS OF ALTITUDE.
ORIFICE SIZE [
F ] DRILL
NORMAL INPUT
[
J ] BTU/HR
THERMAL OUTPUT CAPACITY
[
L ] BTU/HR
MINIMUM INPUT
[
M ] BTU/HR
NORMAL MANIFOLD PRESSURE [
G ] IN.W.C.
MIN. PERMISSIBLE GAS SUPPLY PRESSURE
FOR PURPOSE OF INPUT
ADJUSTMENT.
[
H ] IN.W.C.
CLEARANCES TO COMBUSTIBLE CONSTRUCTION: TOP -12 “,
FLUE CONNECTION - 6”, REAR -18”, SIDE -2 “, DISCONNECT SIDE
- 18”
BOTTOM - 60”, FRONT - 2”
FOR ALTERNATE INSTALLATIONS USE THE LATEST EDITIONS OF
THE APPROPRIATE STANDARD LISTED BELOW:
FOR AIRCRAFT HANGARS
USE STANDARD ANSI/NFPA 409
FOR PARKING STRUCTURES
USE STANDARD ANSI/NFPA 88A
FOR REPAIR GARAGES
USE STANDARD ANSI/NFPA 88B
THIS UNIT IS NOT FOR USE WITH DUCTS.
THIS UNIT IS NOT FOR USE WITH FILTERS.
A Date of ANSI Standard
A’ Date of CSA Standard
B Model No.
C Month and Year of Manufacture
D Voltage, Phase, 60 Hertz, Maximum Total
Input Amps
E Natural or Propane Gas
F Orifice Size
G Manifold Pressure (3.5”w.c. Natural Gas;
10”w.c. Propane Gas)
H Minimum Gas supply Pressure (5.0” w.c.
Natural Gas; 11.0” w.c. Propane Gas)
J BTU Normal Input Sea Level
L BTU Thermal Output Sea Level
M BTU Minimum Input Sea Level
Year
Jan
Feb
Mar
Apr
May
June
July
Aug
Sept
Oct
Nov
Dec
2004
BDA
BDB
BDC
BDD
BDE
BDF
BDG
BDH
BDI
BDJ
BDK
BDL
2005
BEA
BEB
BEC
BED
BEE
BEF
BEG
BEH
BEI
BEJ
BEK
BEL
2006
BFA
BFB
BFC
BFD
BFE
BFF
BFG
BFH
BFI
BFJ
BFK
BFL
2007
BGA
BGB
BGC
BGD
BGE
BGF
BGG
BGH
BGI
BGJ
BGK
BGL
2008
BHA
BHB
BHC
BHD
BHE
BHF
BHG
BHH
BHI
BHJ
BHK
BHL
2009
BIA
BIB
BIC
BID
BIE
BIF
BIG
BIH
BII
BIJ
BIK
BIL
2010
BJA
BJB
BJC
BJD
BJE
BJF
BJG
BJH
BJI
BJJ
BJK
BJL
2011
BKA
BKB
BKC
BKD
BKE
BKF
BKG
BKH
BKI
BKJ
BKK
BKL
2012
BLA
BLB
BLC
BLD
BLE
BLF
BLG
BLH
BLI
BLJ
BLK
BLL
2013
BMA
BMB
BMC
BMD
BME
BMF
BMG
BMH
BMI
BMJ
BMK
BML
2014
BNA
BNB
BNC
BND
BNE
BNF
BNG
BNH
BNI
BNJ
BNK
BNL
2015
BOA
BOB
BOC
BOD
BOE
BOF
BOG
BOH
BOI
BOJ
BOK
BOL
2016
BPA
BPB
BPC
BPD
BPE
BPF
BPG
BPH
BPI
BPJ
BPK
BPL
2017
BQA
BQB
BQC
BQD
BQE
BQF
BQG
BQH
BQI
BQJ
BQK
BQL
2018
BRA
BRB
BRC
BRD
BRE
BRF
BRG
BRH
BRI
BRJ
BRK
BRL
2019
BSA
BSB
BSC
BSD
BSE
BSF
BSG
BSH
BSI
BSJ
BSK
BSL
2020
BTA
BTB
BTC
BTD
BTE
BTF
BTG
BTH
BTI
BTJ
BTK
BTL
Printed Forms (Request by Form designation; not P/N) ........................ Form ....................P/N
Installation/Operation/Maintenance Manual - Model LDAP ....................I-LDAP .................207733
Gas Conversion Instructions ...............................................................I-LDAP-GC .............208881
High Altitude (above 6000 ft) Instructions ...........................................I-LDAP-HA..............208081
Website (downloadable files of all printed forms are on the Website)
www.ReznorHVAC.com
References