Reznor R8HE Option - Installation - Gas/High Alt. Conv. User Manual
Warning, User's manual

LP & HIGH ALTITUDE LP GAS CONVERSION KIT
FOR INSTALLATIONS IN THE UNITED STATES
FOR R8HE / PPG3HE SERIES, CONDENSING STYLE, GAS / ELECTRIC PACKAGE UNITS
BEFORE THE CONVERSION
IMPORTANT: Please read all instructions before
converting the unit. Pay attention to all safety warnings
and any other special notes highlighted in the manual.
Safety markings are used frequently throughout this
manual to designate a degree or level of seriousness and
should not be ignored.
WARNING indicates a potentially
hazardous situation that if not avoided, could result in
personal injury or death.
CAUTION indicates a potentially
hazardous situation that if not avoided, may result in minor
or moderate injury or property damage
This conversion kit is only to be used to convert natural gas
uits to LP/Propane gas in the United States. For installations
in Canada, the Canadian conversion kit must be used.
Table 1 is a detailed listing of the components in the LP
gas conversion kit. Please check the contents of the
conversion kit with that of the parts listing, and familiarize
yourself with each component.
WARNING:
All gas piping must conform with local building
codes, or in the absence of local codes, with the
most recent edition of the National Fuel Gas Code
ANSI Z223.1. DO NOT attempt to modify, or tap
into existing gas lines yourself. Fire or explosion
may result causing property damage, personal
injury or loss of life. Failure to follow the safety
warnings exactly could result in serious injury,
death or property damage.
WARNING:
All electrical wiring must comply with the latest
edition of the National Electrical Code ANSI/
NFPA 70. Failure to follow these instructions
could result in possible damage to equipment,
serious personal injury, or death.
IMPORTANT: The installer performing this work assumes
all responsibility for this conversion. These instructions
are primarily intended to assist qualified individuals
experienced in the proper installation of these components.
Some local codes require licensed installation/service
personnel for this type of equipment. Safety should always
be the deciding factor when installing this product and using
common sense plays an important role as well. Improper
installation of the components or failure to follow safety
warnings could result in serious injury, death, or property
damage. After completing the installation, return these
instructions to the Homeowner’s Package for owner-user’s
future reference.
Table 1. LP Gas Conversion Kit
DESCRIPTION
NORDYNE
P/N
QTY
Honeywell Conversion Kit 50033841
(to convert VR9205Q1127)
624805
1
#55 Drill Size Burner Orifice Kit
(contains (7) 661055)
150602
1
#56 Drill Size Burner Orifice Kit
(contains (7) 661056)
272221
1
Conversion Warning Label
703935
1
Conversion Information Label
703942
1
Installation Instructions
709635
1
WARNING
FIRE OR EXPLOSION HAZARD
• Failure to follow safety warnings exactly
could result in serious injury or property
damage.
• Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
• Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a
neighbors phone. Follow the gas suppliers
instructions.
• If you cannot reach your gas supplier, call
the fire department.
DO NOT DESTROY. PLEASE READ CAREFULLY &
KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.