beautypg.com

PRG Mbox Director User Manual v3.6.1 User Manual

Page 14

background image

8

MBOX

®

DIRECTOR USER MANUAL

Step

4. Launch MBOX application (if the MBOX application is not already running).

Step

5. At MBOX main window, click on Setup tab.

Step

6. At Network section, set Sync to Ethernet 1 and CITP to Local as shown below. Also, set Single Output

Setup to Output 2.

Step

7. When MBOX is launched, it will atomically launch the MBOX Daemon application. Confirm that MBOX

Daemon is running by pressing [

 D] (while MBOX server is in Window mode).

Step

8. At MBOX Daemon window, verify that Network Interface reads: Local. (It should update automatically.)

Step

9. At this point, MBOX Director will be synchronized with the MBOX server. Proceed to

"Adding Fixtures"

on

page 12.

Note: It is not possible to
operate the MBOX server
in a dual output
configuration in Fullscreen
mode while using MBOX
Director on the same
computer. Refer
to

"Changing Configuration

/ Using Dual Output
Features"

on page 14