Network configuration – PRG Mbox Director User Manual v3.8a User Manual
Page 11

MBOX
®
DIRECTOR USER MANUAL
5
Network Configuration
When first setting up Mbox Director, it is important to configure the network settings properly so the application will 
detect the Mbox server (or servers). This is especially critical when running Mbox Director on a separate Mac 
computer, since the network setup will be more involved than when running it locally on an Mbox server. 
Mbox CITP Setting
The network CITP setting should always be configured at the Mbox Setup tab. This setting is located in the Network 
Ports section of the Setup tab as shown below:
Mbox Daemon
Mbox network communication involves a software 
application called Mbox Daemon. This software is required 
on all Mbox servers to enable remote feedback. When the 
Mbox application is launched (on the Mbox server), it will 
automatically launch the last version of Mbox Daemon used 
on that computer. 
To view the Daemon interface, choose it in the dock or 
press [
 D] while the Mbox application is in Window mode.
The Mbox Daemon screen will always reflect the Network 
Interface setting as configured in the Setup tab (see above). 
The Network Interface setting can be changed at the Mbox 
Daemon screen, however, this is not recommended since 
the setting WILL NOT be retained if the Mbox is restarted. A 
sample Mbox Daemon screen is shown to the right.
Mbox Media Server Training Video Chapter 6: CITP – Streaming Feedback & Thumbnails
Mbox Media Server Training Video Chapter 7: Daemon Application