1-4

Overview

Writer: Weldon W. Rowan Project: Overview Comments:

File Name:SAB_1.DOC Last Saved On:7/2/98 8:29 AM

Unit LEDs

The unit-level LEDs on the HB1004 indicate the status of the power supply and
the percentage of use and collisions on the hub.

Table 1-1

Hub LED Conditions and Descriptions

LED

Status

Description

Power

On

Power supply is operational

Off

Power supply is off

Utilization

Indicates percentage of network utilization

1 Green lit

1% to 5%

2 Green lit

5% to 15%

3 Green lit

15% to 30%

3 Green, 1 Amber lit

30% to 65%

3 Green, 2 Amber lit

Above 65%

Collision

Indicates percentage of network collision count variation

1 Green lit

1% to 3%

2 Green lit

3% to 5%

3 Green lit

5% to 10%

3 Green, 1 Amber lit

10% to 15%

3 Green, 2 Amber lit

Above 15%