CYV15G0404DXB AC Electrical Characteristics
Parameter
Description
Min.
Max
Unit
CYV15G0404DXB Transmitter LVTTL Switching Characteristics
Over the Operating Range
f
TS
TXCLKx Clock Cycle Frequency
19.5
150
MHz
t
TXCLK
TXCLKx Period=1/f
TS
6.66
51.28
ns
t
TXCLKH
TXCLKx HIGH Time
2.2
ns
t
TXCLKL
TXCLKx LOW Time
2.2
ns
t
TXCLKR
TXCLKx Rise Time
0.2
1.7
ns
t
TXCLKF
TXCLKx Fall Time
0.2
1.7
ns
t
TXDS
Transmit Data Set-up Time to
TXCLKx↑ (TXCKSELx ≠ 0)
2.2
ns
t
TXDH
Transmit Data Hold Time from TXCLKx
↑ (TXCKSELx ≠ 0)
1.0
ns
f
TOS
TXCLKOx Clock Frequency = 1x or 2x REFCLKx Frequency
19.5
150
MHz
t
TXCLKO
TXCLKOx Period=1/f
TOS
6.66
51.28
ns
t
TXCLKOD
TXCLKO Duty Cycle centered at 60% HIGH time
–1.9
0
ns
CYV15G0404DXB Receiver LVTTL Switching Characteristics
Over the Operating Range
f
RS
RXCLKx± Clock Output Frequency
9.75
150
MHz
t
RXCLKP
RXCLKx± Period = 1/f
RS
6.66
102.56
ns
t
RXCLKD
RXCLKx± Duty Cycle Centered at 50% (Full Rate and Half Rate when
RXCKSELx = 0)
–1.0
+1.0
ns
t
RXCLKR
RXCLKx± Rise Time
0.3
1.2
ns
t
RXCLKF
RXCLKx± Fall Time
0.3
1.2
ns
t
RXDv–
Status and Data Valid Time to RXCLKx± (RXRATEx = 0, RXCKSELx = 0)
(Full Rate)
5UI–2.0
[24]
ns
Status and Data Valid Time to RXCLKx± (RXRATEx = 1, RXCKSELx = 0)
(Half Rate)
5UI–1.3
[24]
ns
t
RXDv+
Status and Data Valid Time to RXCLKx± (RXRATEx = 0, RXCKSELx = 0)
(Full Rate)
5UI–1.8
[24]
ns
Status and Data Valid Time to RXCLKx± (RXRATEx = 1, RXCKSELx =0)
(Half Rate)
5UI–2.6
[24]
ns
CYV15G0404DXB REFCLKx Switching Characteristics
Over the Operating Range
f
REF
REFCLKx Clock Frequency
19.5
150
MHz
t
REFCLK
REFCLKx Period = 1/f
REF
6.6
51.28
ns
t
REFH
REFCLKx HIGH Time (TXRATEx = 1)(Half Rate)
5.9
ns
REFCLKx HIGH Time (TXRATEx = 0)(Full Rate)
2.9
ns
t
REFL
REFCLKx LOW Time (TXRATEx = 1)(Half Rate)
5.9
ns
REFCLKx LOW Time (TXRATEx = 0)(Full Rate)
2.9
ns
t
REFD
REFCLKx Duty Cycle
30
70
%
t
REFR
REFCLKx Rise Time (20%–80%)
2
ns
t
REFF
REFCLKx Fall Time (20%–80%)
2
ns
Notes
20. Tested initially and after any design or process changes that may affect these parameters, but not 100% tested.
21. The ratio of rise time to falling time must not vary by greater than 2:1.
22. For a given operating frequency, neither rise or fall specification can be greater than 20% of the clock-cycle period or the data sheet maximum time.
23. Parallel data output specifications are only valid if all outputs are loaded with similar DC and AC loads.
24. Receiver UI (Unit Interval) is calculated as 1/(f
REF
* 20) (when TXRATEx = 1) or 1/(f
REF
* 10) (when TXRATEx = 0). In an operating link this is equivalent to t
B
.
25. The duty cycle specification is a simultaneous condition with the t
REFH
and t
REFL
parameters. This means that at faster character rates the REFCLKx± duty cycle
cannot be as large as 30%–70%.