beautypg.com

Power supply - mains, Control connections – OmniSistem PR Solo 1200 User Manual

Page 5

background image

SOLO 1200 EN.doc

5/18


Connect the power cord as follows:

L (live) =brown
E (earth) =yellow/green
N (neutral) =blue

Use the plug provided to connect the mains power to the projector paying attention to the voltage and
frequency marked on the panel of the projector. It is recommended that each projector be supplied
separately so that they may be individually switched on and off.

IMPORTANT
It is essential that each projector is correctly earthed and the electrical installation conforms to
all relevant standards. Power consumption of the SOLO 1200 is 1350W.



Connection between controller and projector and between one projector and another must be made
with 2 core-screened cables, with each core having at least a 0.5mm diameter. Connection to and
from the projector is via cannon 3 pin (which are included with the projector) or 5 pin XLR plugs and
sockets. The XLR's are connected as shown in the figure above.
Note: care should be taken to ensure that none of the pins touch the metallic body of the plug or each
other. The body of the plug is not connected in any way. The SOLO 1200 accepts digital control
signals in protocol DMX512 (1990).
Connect the controller’s output to the first fixture’s input, and connect the first fixture’s output to the
second fixture’s input and connect the rest fixtures in the same way. Eventually connect the last
fixture’s output to a DMX terminator as shown in the figure below.

DMX OUT

DMX IN

DMX IN

DMX OUT

DMX IN

DMX OUT

TERMINATOR

DMX IN FROM

CONTROLLER






POWER SUPPLY - MAINS

CONTROL CONNECTIONS