OmniSistem PR Solo 1200 User Manual
Page 12

SOLO 1200 EN.doc
12/18
192-199
Reverse rotation speed 8
200-207
Reverse rotation speed 7
208-215
Reverse rotation speed 6
216-223
Reverse rotation speed 5
224-231
Reverse rotation speed 4
232-239
Reverse rotation speed 3
240-247
Reverse rotation speed 2
248-255
Reverse rotation speed 1
000-051 Clear
052-102 Prism
1
103-153 Prism
2
154-204 CTB
12 Prisms
205-255 CTO
000-120
0~540º index
121-127
Rotation speed 1
128-135
Rotation speed 2
136-143
Rotation speed 3
144-151
Rotation speed 4
152-159
Rotation speed 5
160-167
Rotation speed 6
168-175
Rotation speed 7
176-183
Rotation speed 8
184-191
stop rotating
192-199
Reverse rotation speed 8
200-207
Reverse rotation speed 7
208-215
Reverse rotation speed 6
216-223
Reverse rotation speed 5
224-231
Reverse rotation speed 4
232-239
Reverse rotation speed 3
240-247
Reverse rotation speed 2
13 Prism
Rotation
248-255
Reverse rotation speed 1
14
Pan & Tilt Speed
(Extended function)
000-255
Adjust Pan&Tilt speed from fast to slow
15
Pan Fine (16Bit)
(Extended function)
000-255
Adjust Pan in 16Bit resolution
16
Tilt Fine (16Bit)
(Extended function)
000-255
Adjust Tilt in 16Bit resolution
17
Gobo Rotation Fine
(Extended function)
000-255
Adjust gobo rotation in 16Bit resolution
000-048 Reserve
049-080 Reset
081-112 Reserve
113-144
Turn lamp off
(stay 10 seconds)
145-223 Reserve
18
Control
(when extended functions
are invalid, shift this
channel to 15
th
channel.
)
224-255
Turn lamp on
(see remark below)
Remark:
If you intend to turn on/off the lamp via the 18
th
channel of the controller, don’t attempt to push the
slide bar of 18
th
channel to value 224-255 immediately after turning it off, or push the slide bar to
value 224-255 to wait it cooling. Under these 2 circumstances, the lamp can not be turned on. The