Oberon 1790 User Manual
Installation instructions, Poe ils
Installation Instructions
PoE ILS
(877) 867-2312 • www.oberonwireless.com
Rev. 02/12/13 P/N 1790
Oberon, Inc. •••• 1315 South Allen Street •••• State College, PA 16801
Copyright 2013
Assembly Components:
- PoE ILS assembly – 1 each
- #8-32 X 3/8 “ screw – 4 each
- Installation instructions – 1 each
If any of these items are missing, contact your Oberon representative.
Find a flat work surface to assemble the ceiling enclosure, PoE ILS, access point and antenna(s) prior to mounting in ceiling.
Step 1 - The PoE ILS is designed to be used with Oberon enclosures. At the time of this writing, the only enclosure that
accommodates the PoE ILS is the Oberon Model 1052-00.
Step 2 – Install the PoE ILS board into the 1052-00
with the four supplied screws. Mount the PoE ILS such
that the switch is facing outward toward the door, as
shown in Figure 1.
Step 3 –
Route the incoming Ethernet cable through
the 1052-00 following the instructions provided with
the enclosure, and insert the RJ-45 connector into the
IN port on the PoE ILS. The port locations are shown
in Figure 2.
Step 4 – Route the incoming Ethernet cable through
the 1052-00 following the instructions provided with
the enclosure, and insert the RJ-45 connector into the
IN port on the PoE ILS. The port locations are shown
in Figure 2.
Page 2
Step 4 – If desired, during WAP testing or maintenance, to provide power to the WAP with the enclosure door open a PC
jumper (customer provided) can be used on the two pin jumper located beside the switch on the PoE ILS board.
Ensure
that the jumper is not left in place during normal operation, or the PoE ILS will be bypassed.
Page 3
Figure 1 - Hardware installation.
Figure 2
Optional Bypass
Jumper Pins
Input Port
Output Port
To WAP