Installation Instructions

Model Number 1052-AN-ANT16

(877) 867-2312www.oberonwireless.com

Rev. 2A 6/05/14

Oberon, Inc. •••• 1315 South Allen Street •••• State College, PA 16801

Copyright 2013




Assembly Components:
- Ceiling enclosure Model 1052-AN-ANT16 assembly – 1 each
- 1” Trade size cable clamps – 2 each
- #8 – 32 screw – 4 each
- #6 – 32 screw – 4 each
- Installation Instructions – 1 each
- Keys for access door lock – 2 each
- Firestop Grommet – 1 each
- Support wire – 4 each

If any of these items are missing, contact your Oberon representative.


Find a flat work surface to assemble the ceiling enclosure, access point and antenna(s) prior to mounting in ceiling.

Step 1 – Place the ceiling enclosure
assembly
on the work surface with the
keyed doorway unlocked. Remove hole
covers located on the outside edge of the
back box to install cable clamps. Install
one cable clamp if using P.O.E. or install 2
cable clamps if bringing in power and
Ethernet and power separately.
























Page 2














Step 2 – (Aruba APs Only) Install the access point so that
the three antenna connectors are facing toward the door
lock. Securely fasten the access point’s mounting plate to
the mounting holes on the back wall of the enclosure using
(4) # 8-32 screws. Attach the screws to the outer hole
pattern. Attach the Access Point to the mounting plate.
Attach antennas to the access point and clip to the door.
Proceed to Step 3.










Step 3 – If applicable, install the Aruba Networks AP-ANT-16 antenna per the instructions included with it. After installation,
connect the RF coax cable from the antenna to the access point.

The assembled unit is now ready for ceiling installation.

Step 4 – Remove the ceiling tile and replace it with the completed access point enclosure assembly.

Step 5 – Use minimum 12-gauge grid wire (included) to attach the access point enclosure to the ceiling. Attach one end of the
wire to the eye tabs located along the edge of the back box and the other end to a permanent structure within the ceiling such
as a ceiling joist.

**IMPORTANT** - This is an important safety feature that could prevent human injury or damage to the access

point should the unit become dislodged from the ceiling.









Page 3