Oberon 1064-T User Manual
Model 1064-t, Warning, Installation instructions
Figure 5 – Pull the data cable through far enough to allow attachment to the access
point (8" - 10"). Snap the grommet around the cable(s).
Step 9 – Place the access point in the opening
of the enclosure (reference Figure 5) with the
access points LED light away from the key
lock. If the key is turned the proper direction,
the access point should drop in and self-
center itself so that the feet on the access
point falls into the key slots on the mounting
plate (reference Figure 6).
NOTE: If the access point and key
slots do not align properly, turn the key
180° and repeat step 5.
Step 10 – After verifying that the access point
is properly seated within the opening, turn the
key 180° to lock the Access Point in place.
The key should require minimal effort to turn.
If excessive force is required to turn the key,
verify that the access point is properly seated
within the opening and then re-try turning the
key.
Page 4
MODEL 1064-T
Installation Instructions
**** WARNING ****
Please thoroughly read the product warning below
before installation to provide for a safe work
environment.
1. Ceiling mounted products should be installed in accordance with National Electric Code paragraphs 300.10 (Electrical
Continuity of Metal Raceways and Enclosures) and 300.11 (Securing and Supporting). Independent support wires or
other means must be used for the installation of this product in the ceiling. Acoustical, suspended, false, drop and
concealed spline ceiling grid work is not designed to support the weight of this product. Oberon’s ceiling mounted
products have four support wire tabs on the back box. These tabs shall be used for supporting the product with
independent support wires, wire rope, threaded rod, or other secure support means of adequate gauge and fire
resistance.
2. When closing the enclosure access door, be sure that the cam lock is completely engaged to prevent the access door
from accidentally swinging open.
3. When opening the enclosure door, be sure to support the door to prevent the door from accidentally falling open.
4. This enclosure has a maximum operating ambient of 55º C (131º F), the temperature within the enclosure may not
exceed this temperature, depending on power dissipation within enclosure.
5. A minimum air clearance of 1“ between the housing of the access point and the enclosure side walls must be
maintained for the safe operation of the equipment.
6. This product is intended to be installed by trained personnel.
7. Only Listed ITE shall be installed within the enclosure.
8. This product is to be repaired by personnel trained by the manufacturer or returned to the manufacturer for repair or
replacement.
9. Maximum weight to be installed in the unit is 25 lbs.
10. All knockouts, openings, and holes shall be sealed with a plug constructed of metal, or a non-metal material that
complies with UL 2043 or UL 1479.
11. All unused mounting holes should be sealed with tape or other material that complies with UL 1479.
12. If AC power is used inside the enclosure, connect the ground wire to the green ground screw located near the
knockout in the backbox.
Page 1
Figure 6 – Proper positioning of AP within the 1064 enclosure. Note that the
access point should be located within the AP mount so that the LED is located
closest to the lock