Oberon 38-52-AP105 User Manual
Installation instructions
Installation Instructions
Model Number 38-52-AP105
Assembly Components:
- Door Assembly – 1 each
- #4 – 40 shoulder screw – 2 each
(877) 867-2312
www.oberonwireless.com
Rev. 7/25/11
Oberon, Inc.
1315 South Allen Street State College, PA 16801
Copyright 2011
- #8 – 32 hex nuts – 4 each
If any of these items are missing, contact your Oberon representative.
Tools required: Screwdriver & Wrench Set
Find a flat work surface to assemble the mounting plate, access point, and door.
Step 1 – Install the (2) # 4-40
shoulder screws into the mounting
plate. Orient the access point so
that the locking keyway slots on the
back line up with the shoulder
screws and the access point is
centered on the bracket. Attach the
access point by sliding it over the
shoulder screws (Figure 1).
Step 2 – The door assembly is completed by attaching
the previously assembled mounting plate/access point
assembly to the enclosure door by securing it in place
with four (4) #8-32 hex nuts. Place the slotted holes in
the mounting plate/access point assembly over the
studs located on the bottom side of the door (NOTE:
the mounting plate can only be attached to the door in
one direction. If the slotted holes don’t match up with
the studs in the door, rotate the mounting plate 180°).
Once the mounting plate is positioned, secure it in
place by installing four (4) #8-32 hex nuts (Figure 2).
Page 2
Final Assembly
Step 3 – Remove the current door (if not previously done)
and replace it with the new door assembly. To remove the
old door, open the enclosure and remove the three (3) hex
nuts holding the door in place (Figure 3).
NOTE: If required, remove lock from old door and
replace on new door.
Figure 3
Figure 1
Figure 4
Figure 2
Step 4 – Install the door assembly by placing the three (3)
mounting holes in the door over the studs on the hinge and
then replace the nuts (Figure 4).
Page 3