Installation instructions – Oberon 1077-AP225 User Manual
Page 2
Installation Instructions
Model Number 1077-AP225
(877) 867-2312
•
www.oberonwireless.com
Rev. A1 03/7/14
Oberon, Inc.
•
1315 South Allen Street
•
State College, PA 16801
Copyright 2014
Assembly Components:
- Ceiling enclosure Model 1077-AP225 assembly – 1 each
- T-bar mount – 1 each
- Mounting bracket – 1 each
- ¾” Trade size conduit connectors – 1 each
- Fire Block Foam – 1 each
- #8 – 32 wing nut – 2 each
- Lock washer – 2 each
- Support wire – 4 each
- Installation Instructions – 1 each
- Keys for access door lock – 2 each
If any of these items are missing, contact your Oberon representative.
Find a flat work surface to assemble the ceiling enclosure,
access point and antenna(s) prior to mounting in ceiling.
Step 1 – Place the ceiling enclosure assembly on the work
surface with the keyed doorway unlocked. Remove hole knock
outs located on the outside edge of the back box to install
conduit connectors. Install one conduit connector if using
P.O.E. or install 2 conduit connectors if bringing in power and
data separately (Figure 1).
Step 2 – Snap Aruba
Networks t-bar clip onto
the t-bar mount by
angling at a 45° angle
and twisting the clip
until it snaps in place.
Next, attach the access
point
to
the
Aruba
Networks t-bar clip by
angling
the
access
point at a 45° angle and
twisting it until it also
snaps in place (Figure
2).
Page 2
Step 3 – Align the threaded studs to the two outer holes in the bracket attached to the door. Once the access point is snug in
the hole, place the lock washer and wing nut onto the threaded rod. Tighten wing nuts until they are snug. With your fingers,
tighten the hex nuts on the underside of the bracket then re-tighten the wing nuts until they no longer move freely (Figure 3).
Step 4 – For added security, attach wire ties to the two inner holes of the bracket and the t-bar mount. Make sure securely
fasten the wire ties in place.
Step 5 – Remove the ceiling tile and replace it with the completed access point enclosure assembly.
Step 6 – Use minimum 12-gauge support wire (included) to support the access point enclosure independently of the ceiling
grid. Attach one end of the wire to the support wire tabs located along the edge of the back box and the other end to a
permanent supporting structure within the ceiling such as a ceiling joist (Figure 4).
**IMPORTANT** - This is an important safety feature that could prevent human injury or damage to the access
point should the unit become dislodged from the ceiling.