beautypg.com

2 boom-frame roll sensor mounting, 3 chassis roll sensor mounting – NORAC UC5-BC-HG03 User Manual

Page 18

background image



15

7.2

Boom-Frame Roll Sensor Mounting

1. Install the roll sensor with the lowest serial number onto the top part of the center boom

section on the left hand side of the boom. The roll sensor must be mounted with the

connector facing the right boom.

Figure 13: Hagie Boom Frame Roll Sensor Mounting

Ensure the boom frame roll sensor does not collide with any parts and the cable
has sufficient slack for the boom to travel though its entire range of motion.

7.3

Chassis Roll Sensor Mounting

1. Mount the roll sensor with the highest serial number on the main sprayer chassis, with the

cable facing the right hand wing.

2. A common mounting location is in front of the left hand side air bag, near the location

where the main lift cylinder attaches to the frame.

Figure 14: Hagie Boom Frame Roll Sensor Mounting