7 Roll Sensor Installation

7.1

Bracket Assembly

1. Securely mount the roll sensors to the included roll sensor brackets using the #6 hex head

machine screws provided (M05). Tighten screws to 10 in-lbs (1.1 Nm).

2. The orientation of both roll sensors to the roll sensor bracket will depend on the bracket

mounting. The roll sensor CANbus connector must be pointing towards the right side of
the sprayer.

Figure 11: Mounting Roll Sensor to Bracket


Figure 12: Roll Sensor Orientation - Connector Facing Right Wing