Figure 15: Roll Sensor Mounting with Respect to Sprayer Orientation

4.5.1 Boom Frame Roll Sensor

Mounting

The boom roll sensor (E04) must be
mounted to the rotating part of the boom.
Follow these guidelines and refer to Figure
14
and Figure 16 to mount the sensor.

a) Make sure you are using a roll sensor

that does NOT have a temperature

probe (only one cable) with the lowest
serial number (E04).

b) The boom roll sensor must be mounted

to the rotating part of the boom
suspension.

c) Use cable-ties to secure the bracket to

a square edge feature (square tube).

d) Ensure the AMP (circular) connector

exits towards the Right Hand Wing
(when looking from the rear of the
sprayer).

e) Securely cable-tie the connector to the

frame.

4.5.2 Intermediate Frame Roll Sensor

Mounting

The intermediate roll sensor must be
mounted to a non-rotating part of the
boom. To mount the chassis roll sensor,
follow the following guidelines and refer to
Figure 14 and Figure 16.

a) Make sure you are mounting the roll

sensor that does have a temperature
probe (2 cables) (E03).

b) Mount the intermediate roll sensor

(E03) to a non-rotating part of the
boom.

c) Cable-tie the bracket to a square edge

feature (square tube).

d) The AMP (circular) connector MUST

exit towards the Right Hand Wing
(when looking from the rear).

e) Make sure the temperature probe is

able to reach the side of the valve block.

f) Securely cable-tie the connector to the

frame.

* The boom frame and

chassis roll sensors do

not have temperature
probes