NORAC UC4+BC+CS5 User Manual
Page 28
26
Figure 30: Cable Configurations: C10, C11 and C14
2. Connect the UC4+ power cable (C10)
to the UC4+ control panel in the
sprayer cab. Ensure both plugs (P16
and P4) are connected to the panel.
3. Connect the 3-pin AMP plug (P3) on
C10 to the 3-pin AMP receptacle (R3)
on the power pigtail interface cable
(C14). Splice the pigtails on C14 into
the existing wiring.
Ensure the UC4 control panel’s
power is OFF for the remaining
installation (Bottom of switch
pressed IN). Use caution when
handling the 12 V power line of
the existing wiring.
4. Route the receptacle end (R16) of C10
out of the cab.
5. Connect the 16-pin AMP plug (P16) of
the valve extension cable (C11) to R16
of C10 on the outside of the cab
(Figure 30).
6. Route C11 to the rear of the sprayer,
in the vicinity of the valve block.
7. Connect the unplugged 6-pin shroud on
cable C17 to the 6-pin tower on cable
C11.
8. Connect the 3-pin shroud labeled
“Connect to C11” on cable C17 to the
3-pin tower on cable C11.
9. Connect the 6-pin shroud on the
interface cable (C12) to the mating 6-
pin tower on C17.
10. Connect the 3-pin tower (T3) on cable
C16 to the mating connector (S3) on
C11.
11. Route the free end of cable C16 to the
existing left and right boom control
valve block.
12. Insert the 2-pin tees (R2A-P2A - R2D-
P2D) of C16 between the matching
valve connections (Left Up, Left Down,
Right Up, Right Down).