3 boom frame roll sensormounting – NORAC UC4+BC+CS5 User Manual
Page 21
19
4.5.3 Boom Frame Roll Sensor
Mounting
The remaining roll sensor after
installing the Intermediate and
Chassis Roll sensors is the Boom
Frame Roll sensor
1. Use the supplied hardware to mount
the boom frame roll sensor (E04) as
shown in Figure 21.
When mounting the boom frame roll
sensor follow these guidelines:
a) To prevent bending the bracket,
ensure bolts are placed as close
together as possible (minimize C in
Figure 21).
b) Be sure to use the roll sensor
without the temperature probe
(E04).
c) When the boom is centered (not
rolled over) the roll sensor should
be level with respect to the sprayer
chassis.
d) It is best to mount the roll sensor to
the left hand trapeze link (when
looking from the rear of the
sprayer).
e) The roll sensor AMP (circular)
connector MUST exit towards
the right had wing (when looking
from the rear of the sprayer).
Figure 21: Boom Frame Roll Sensor
Mounted to a Trapeze Link
2. Cable-tie the sensor connector to the
frame with enough slack to allow the
link to rotate.
Make sure the bracket does not
collide with any parts of the
sprayer when the boom rotates.
Also ensure there is enough slack
to allow the roll sensor to rotate.