4.6.2 Valve Mounting
1. Mount the NORAC valve (V01) on the
sprayer using the valve mounting
bracket (B10).
2. Screw short side of the threaded rods
into the bottom of the valve block at
least 3/8". The valve mounting holes are
drilled and tapped 3/8 NC-1" deep.
3. Tighten the Hex nuts to hold the rods.
4. Put the mounting bracket on the other
side of the tube and tighten with the
spring washers and the Hex nuts.
5. Cut excess off of the rods, if necessary.
If using bolts, the bolts should
thread into the valve block at
least 3/8". The valve mounting
holes are drilled and tapped 3/8
NC-1" deep. The rule of thumb
for bolt length is 1-1/2" longer
than the tube size.
The recommended location for
the valve is on top of the hose
mounting frame located close to
the top of the boom. The frame
is made from smaller tubing
projecting rearward from the
main boom. (Figure 25)
You must ensure no hydraulic
components will interfere with
any sprayer parts or be pulled
tight at any time.
Figure 24: Valve Mounting Location