beautypg.com

NORAC UC4.5-BC-RA1 User Manual

Page 24

background image



21

Figure 25: RAU Module Wiring

7. Connect the 3 Weatherpack connectors on C17 to the mating connectors on C11.

Connect the RAU Valve Drive PCB (C12) to C17.

8. Plug C18 into C12 and securely fasten the module to the sprayer with cable-ties.

9. Connect Item C19 into Item C18:

a. Remove the green plastic Deutsch pin lock with a flat screwdriver.
b. Insert the pin on harness C19 into position 3 of C18.
c. Replace the Deutsch pin lock.
d. Connect the other end of C19 to the bypass valve (located at the front of the sprayer).

Tee the cable DIN connectors between the bypass valve DIN connector.

Figure 26: Cable C19 Connected to RAU Bypass Coil