beautypg.com

7 main lift sensor installation – NORAC UC4.5-BC-RA1 User Manual

Page 19

background image



16

5.7 Main Lift Sensor Installation

1. The Main lift sensor bracket (B11) can be mounted as illustrated below. Ensure the cable is

safely routed to prevent damage from moving parts.

Figure 17: Main Lift Sensor Bracket Mounting - View from Beneath the Boom

2. In order to fit the bracket within the boom as illustrated, it is necessary to cut 90mm from

the bracket, and drill a new 10mm hole for the sensor, 12 mm from the tip.

Figure 18: Modification to Bracket 44695-4

90mm

12 mm