beautypg.com

2 boom roll sensor mounting, 3 chassis roll sensor mounting – NORAC UC4.5-BC-RA1 User Manual

Page 21

background image



18

6.2 Boom Roll Sensor Mounting

1. Mount the boom roll sensor (E03) to the rolling part of the boom. Ensure that this is the

roll sensor with the temperature probe. This is accomplished by drilling and bolting to the

sheet-metal frame. Mount the roll sensor as illustrated, oriented with the CAN cable
pointing to the right-hand wing (when looking from the rear of the sprayer).

Figure 21: Boom Frame Roll Sensor

6.3 Chassis Roll Sensor Mounting

1. Mount the chassis roll sensor (E04) to the square tube. Ensure that this is the roll sensor

without the temperature probe. Orient the sensor so the CAN connector points towards

the right-hand boom (when looking from the rear of the sprayer) and ensure the cables are
routed and fastened properly. Use the mounting bracket and cable ties to fasten sensor to
the square tube.

Figure 22: Roll Sensor Mounted to Non-Rotating Boom Centerpart