Dead short – Muchmore CTX D2 User Manual
Page 6

7.DEAD SHORT
E4
Determine discharge
cut off voltage(0.20V~1.20V).
Discharged time
2.DEAD SHORT
3.PULSE DCH
0.00 0.00 0.00
0.00 0.00 0.00
1.48 1.47 1.48
1.48 1.48 1.47
1.38 1.38 1.37
1.38 1.38 1.37
2347 2321 2201
2256 2254 2227
DELY DELY DELY
ELAPSED TIME
00:00:08
DEAD SHORTING
00:29:56
DEAD SHORT DONE
00:00:03
Average voltage at cut off voltage(0.90V).
1.24 1.24 1.23
1.23 1.25 1.24
DEAD-SHORT START
CUT OFF VOLT
0.90V
00:01:00
Determine Dead short time.
(1min~24Hour)
DEADSHORT TIME
0.90V
00:30:00
Tray your battery pack on the
CTX-D2. Make sure battery pack's
polarity and direction are correct.
Tighten 12screws tight in order
to get exact data.
Each cell's voltage showing up.
Current voltage is displayed.
Once each cell's voltage is reached to the cut-off voltage, the
cell is monitored as DELY(delaying).
Once all cells voltage is reached to the cut-off voltage, Dead
shorting begins.
Remaining time is displayed.
Elapsed time is displayed after Dead short done.
0.95 DELY 0.91
Dead short mode discharges your cells at linear
5Amp until the cut-off voltage is reached. Once all
your cells voltage reaches to the cut-off voltage,
the CTX-D2 starts Dead shorting until the dead
short time finishes.
You'll never have to worry about damaging your
batteries because discharge stops by deadshort
time setting.
Average volt and discharged time will be monitored
after discharge ends.