Linear discharge – Muchmore CTX D2 User Manual
Page 5

6.LINEAR DISCHARGE
E3
Determine discharging
cut off voltage(0.20V~1.20V).
Discharged time
1.LINEAR DCH
2.DEAD SHORT
0.00 0.00 0.00
0.00 0.00 0.00
1.48 1.47 1.48
1.48 1.48 1.47
1.48 1.47 1.48
1.48 1.48 1.47
1.38 1.38 1.37
1.38 1.38 1.37
2347 2321 2201
2256 2254 2227
DONE DONE DONE
ELAPSED TIME
00:00:08
DISCHARGE DONE
00:00:15
Average voltage at cut off voltage(0.90V).
1.24 1.24 1.23
1.23 1.25 1.24
LINEAR DCH START
CUT OFF VOLT
0.90V
Tray your battery pack on the
CTX-D2. Make sure battery pack's
polarity and direction are correct.
Tighten 8screws tight in order to
get exact data.
Each cell's voltage showing up.
Current voltage is displayed.
No.1, 2, 3, 5 cell discharge done.
No.4 and 6 still discharging.
0.95 DONE 0.91
Linear discharge mode discharge each cell individually at 5A linear current.
Discharged time(seconds), Average volt are provided after discharge ends.
When reading data, match numbers
on the tray to numbers on the LCD.
matching
data
5A linear dch.
30A pulse dch.
ext. port
dead short
accurate data