beautypg.com

Linear discharge – Muchmore CTX D2 User Manual

Page 5

background image

6.LINEAR DISCHARGE

E3

Determine discharging

cut off voltage(0.20V~1.20V).

Discharged time

1.LINEAR DCH

2.DEAD SHORT

0.00 0.00 0.00

0.00 0.00 0.00

1.48 1.47 1.48

1.48 1.48 1.47

1.48 1.47 1.48

1.48 1.48 1.47

1.38 1.38 1.37

1.38 1.38 1.37

2347 2321 2201

2256 2254 2227

DONE DONE DONE

ELAPSED TIME

00:00:08

DISCHARGE DONE

00:00:15

Average voltage at cut off voltage(0.90V).

1.24 1.24 1.23

1.23 1.25 1.24

LINEAR DCH START

CUT OFF VOLT

0.90V

Tray your battery pack on the

CTX-D2. Make sure battery pack's

polarity and direction are correct.

Tighten 8screws tight in order to

get exact data.

Each cell's voltage showing up.

Current voltage is displayed.

No.1, 2, 3, 5 cell discharge done.

No.4 and 6 still discharging.

0.95 DONE 0.91

Linear discharge mode discharge each cell individually at 5A linear current.

Discharged time(seconds), Average volt are provided after discharge ends.

When reading data, match numbers

on the tray to numbers on the LCD.

matching

data

5A linear dch.

30A pulse dch.

ext. port

dead short

accurate data