CHAPTER 4 - Maintenance/Troubleshooting

he D51T Dialer is built to require minimal maintenance. Only the system battery
requires your attention from time to time for your dialer to continue performing
with no problems.

INTERNAL RECHARGEABLE BATTERY

: A battery in typical standby use

will last approximately 2 to 4 years. Battery life is mostly dependent upon the number of
power outages sustained and the age of the battery, and temperature. A new battery
should take no longer than 72 hours to gain full charge, capable of powering the system
through a power outage of greater than 24 hours. Battery backup time may vary
depending upon the age of the battery and the frequency and duration of alarm callouts
which occur while the dialer is operating on the standby battery.

FUSE:

D51T features an internal, resettable fuse which never requires service. If you

can measure 12 – 20 VDC at the external power input terminal block, but the AC
POWER/CHARGING LED is OFF, the fuse may have blown. Remove power from
D51T by turning OFF the Power switch and unplugging the removable External Power
Terminal Block. Wait for about a minute for the fuse internal to the dialer to cool down,
then plug the power back in. If the AC POWER/CHARGING LED comes ON briefly
then goes OFF, the fuse is blowing. Blown fuses can be indicative of other problems.
Measure the input power supply, and verify that it is 12 – 20 VDC. A high external
voltage may cause the fuse to blow. If the fuse continues to blow and the external power
is within specifications call the factory.

T