VIN_OFF

Reference:

Standard Command

Lockable:

Yes

Command Code:

0x36

Format:

Linear

Data Bytes:

2

Units:

V

Transfer:

Read/Write Word

Factory Value:

0xCAC0 (5.5V)

Description/Notes: See Section 14.6 of the PMBus Specification Part II.

The MAX15301 hardware has 8-bit resolution for the minimum input voltage required for regulation,
to a maximum value of ≈14.75V.

The desired value of VIN_OFF is retained in memory, regardless limitations imposed by the 8-bit fault