Vout_uv_fault_limit, Vout_uv_fault_response, Iout_oc_fault_limit – Maxim Integrated MAX15301 PMBus Command Set User Manual

Page 22

background image

MAX15301 PMBus Command Set User’s Guide

Rev 1

Page 22 of 53

VOUT_UV_FAULT_LIMIT

VOUT_COMMAND

x 0.85, unless a specific value has been written to the User Store.

VOUT_UV_FAULT_RESPONSE

Reference:

Standard Command

Lockable:

Yes

Command Code:

0x45

Format:

Bit field

Data Bytes:

1

Units:

N/A

Transfer:

Read/Write Byte

Factory Value:

0x00 (Ignore undervoltage faults)

Description/Notes: See Sections 10.5.1 and 15.7 of the PMBus Specification Part II.

Note that the MAX15301 does not support finite, non-zero restart-attempt counts. (Continuous
restart attempts are supported.)

The VOUT_UV_FAULT_RESPONSE command data comprises three bit-fields:

Bits [7:6] determine the basic fault-response mode. The MAX15301 supports the following modes:

00

Ignore the fault condition. (Default setting)

01

Continue operating and wait for the fault to abate for time specified in bits [2:0]. If the

fault does not abate, shutdown and attempt to restart according to bits [5:3].

10

Stop regulating immediately, delay for the time specified in bits [2:0], then attempt to

restart according to bits [5:3].

11

Stop regulating immediately, and then restart as soon as possible after the fault

condition abates.

Bits [5:3] determine the number of retry attempts. The MAX15301 supports only a subset of the full
PMBus functionality for this portion of the command:

000-110

No attempt is made to restart after a fault shutdown. (Default setting)

111

Attempt to restart continuously until commanded off, or until another fault

condition causes the unit to shut down.

Bits [2:0] determine the fault-tolerance or retry-delay timing. Each binary value in bits [2:0]
corresponds to a multiple of 100ms, up to a possible maximum of 111

bin

= 700ms. A value of 000

bin

will cause the MAX15301 to use the minimum possible timing value, typically about 30-40ms. (The
default timing for undervoltage faults is
000

bin

.)

IOUT_OC_FAULT_LIMIT

Reference:

Standard Command

Lockable:

Yes

Command Code:

0x46

Format:

Linear

Data Bytes:

2

Units:

A

Transfer:

Read/Write Word

Factory Value:

0xDB20 (25A)

Description/Notes: See Section 15.8 of the PMBus Specification Part II.

The MAX15301 hardware has 8-bit resolution for the overcurrent fault limit within a 30A full-scale
load current range.

The desired value of IOUT_OC_FAULT_LIMIT is retained in memory, regardless limitations imposed by
the 8-bit fault limit resolution, but the read-back value is based on actual hardware register settings.