beautypg.com

Read_frequency, Pmb_values – Maxim Integrated MAX15301 PMBus Command Set User Manual

Page 32

background image

MAX15301 PMBus Command Set User’s Guide

Rev 1

Page 32 of 53

READ_FREQUENCY

Reference:

Standard Command

Lockable:

N/A

Command Code:

0x95

Format:

Linear

Data Bytes:

2

Units:

kHz

Transfer:

Read Word

Factory Value:

N/A

Description/Notes: See Section 18.10 of the PMBus Specification Part II.

The READ_FREQUENCY command returns the actual switching frequency in kilohertz.

The desired switching frequency is set using the

FREQUENCY_SWITCH

command.

PMB_VALUES

Reference:

Maxim Specific

Lockable:

Yes

Command Code:

0xF5

Format:

See Description

Data Bytes:

215

Units:

See Description

Transfer:

Read/Write Block

Factory Value:

See Description

Description/Notes:

This command returns most PMBus command values from the device for ease of recording the device
configuration. The command data returned is as follows: