VIN_UV_FAULT_RESPONSE

restart according to bits [5:3].

11

Stop regulating immediately, and then restart as soon as possible after the fault

condition abates. (Default setting)

Bits [5:3] determine the number of retry attempts. The MAX15301 supports only a subset of the full
PMBus functionality for this portion of the command:

000-110

No attempt is made to restart after a fault shutdown. (Default setting)

111

Attempt to restart continuously until commanded off, or until another fault

condition causes the unit to shut down.

Bits [2:0] determine the fault-tolerance or retry-delay timing. Each binary value in bits [2:0]
corresponds to a multiple of 100ms, up to a possible maximum of 111

bin

= 700ms. A value of 000

bin

will cause the MAX15301 to use the minimum possible timing value, typically about 30-40ms. (The
default timing for input undervoltage faults is
000

bin

.)