VOUT_OV_FAULT_RESPONSE

Reference:

Standard Command

Lockable:

Yes

Command Code:

0x41

Format:

Bit field

Data Bytes:

1

Units:

N/A

Transfer:

Read/Write Byte

Factory Value:

0x80 (Stop regulating and remain off)

Description/Notes: See Sections 10.5.1 and 15.3 of the PMBus Specification Part II.

Note that the MAX15301 does not support finite, non-zero restart-attempt counts. (Continuous
restart attempts are supported.)

The VOUT_OV_FAULT_RESPONSE command data comprises three bit-fields:

Bits [7:6] determine the basic fault-response mode. The MAX15301 supports the following modes:

00

Ignore the fault condition.

01

Continue operating and wait for the fault to abate for time specified in bits [2:0]. If the

fault does not abate, shutdown and attempt to restart according to bits [5:3].

10

Stop regulating immediately, delay for the time specified in bits [2:0], then attempt to

restart according to bits [5:3]. (Default setting)

11

Stop regulating immediately, and then restart as soon as possible after the fault

condition abates.

Bits [5:3] determine the number of retry attempts. The MAX15301 supports only a subset of the full
PMBus functionality for this portion of the command:

000-110

No attempt is made to restart after a fault shutdown. (Default setting)

111

Attempt to restart continuously until commanded off, or until another fault

condition causes the unit to shut down.

Bits [2:0] determine the fault-tolerance or retry-delay timing. Each binary value in bits [2:0]
corresponds to a multiple of 100ms, up to a possible maximum of 111

bin

= 700ms. A value of 000

bin

will cause the MAX15301 to use the minimum possible timing value, typically about 30-40ms. (The
default timing for overvoltage faults is
000

bin

.)

VOUT_UV_FAULT_LIMIT

Reference:

Standard Command

Lockable:

Yes

Command Code:

0x44

Format:

Unsigned integer mantissa

Data Bytes:

2

Units:

V

Transfer:

Read/Write Word

Factory Value:

0x019A (see Description)

Description/Notes: See Section 15.6 of the PMBus Specification Part II.

VOUT_UV_FAULT_LIMIT mantissa data sent to and from the MAX15301 must be divided by 4096 to
determine the actual voltage value, according to the fixed value of

VOUT_MODE

.

In the MAX15301, there are seven possible output voltage ranges based on seven corresponding
internal feedback divider taps. The MAX15301 hardware has 8-bit resolution for the undervoltage
fault limit within each of these seven ranges.

The desired value of VOUT_UV_FAULT_LIMIT is retained in memory, regardless of limitations
imposed by the feedback divider range and the 8-bit fault limit resolution, but the read-back value is
based on actual hardware register settings.

The factory value of 0x019A (0.100V) will be overridden during initialization to