beautypg.com

5 repeat command, Repeat command – Maxim Integrated 78M6631 User Manual

Page 31

background image

UG_6631_078

78M6631 Firmware Description Document

Rev 2

31

7.3.5 Repeat Command

The repeat command can be useful for monitoring measurements and is efficient in demands from the

host.

If the host requests line frequency, alarm status, Irms overcurrent event count, Vrms overvoltage event

count, voltage, power, and accumulated energy measurements with the following command string:

>)21????????

If the host then desires this same request without issuing another command, the repeat command can be

used:

>, (no carriage return needed for the repeat command)

The host only needs to send one character rather than an entire string.

Auxiliary

Description:

Various

Commands:

,

Typing a comma (“,”) repeats the command

issued from the previous command line. This is

very helpful when examining the value at a

certain address over time, such as the CE

DRAM address for the temperature.

/

The slash (“/”) is useful to separate comments

from commands when sending macro text files

via the serial interface. All characters in a line

after the slash are ignored.