6.2
Overview
Function
Available
settings
Description
F0 bk
Display background
illumination
bk on
Background illumination on
bk off
Background illumination off
bk AU
Background illumination switches on
automatically when loaded or a button is
pressed
F1 AZ
Autozero
AZ 0.5d
Automatic zero correction (auto-zero) on change of
display,
Selectable digits available
0.5d,1d, 2 d, 4 d.
AZ 1d
AZ 2d
AZ 4d
F2 Unt
Standard weighing
unit
Ut lb
Pound
Ut kg
Kilogram
Ut N
Newton
F3 CHk
Check weighing
Ck Lo
Lower limit value, input see chap. 5.9
Ck Hi
Upper limit value, input see chap. 5.9
F4 CAP
Capacity
1000 kg
Weighing range [Max],
options
1000 / 2000 / 3000 / 5000 /
10000 kg
Modifications may
only be carried out
by a specialist with
competent
knowledge.
2000 kg
3000 kg
5000 kg
10 000 kg
F5 CAL
Adjustment /
linearization
nonLi
Adjustment
Line
Linearization
F6 isp
XXXXX
Internal A/D converter value
F7 GrA
Not documented
F8 rst
Reset to default setting
F9SPd
Display speed
SPd 7.5
SPd 15
SPd 30
SPd 60
F10of
Autom. switch-off
function
(auto off)
Off 0
Off 0: Autom. switch-off function disabled
Off 3
Off 3/5/15/30: Balance will switch off after x
minutes in stand-by mode.
Off 5
Off 15
Off 30
* = default setting
HFA-BA-e-1511