4 totalization, Totalization – KERN & SOHN VFS 2T1 User Manual
Page 24

VFS-BA-e-1111
24
7.4 Totalization
The display unit offers an option that allows the addition of weighing values and the
display of the total weight. If a tare weight is active, the net weight is automatically
added up.
Ö No load may be on the loading fork
Ö The system should be stable (stability display „STABLE“
illuminated)
Ö The added-up weighing value must be more than 20d.
Ö Loading the system with the load to be added
Ö Wait for stability display „STABLE“, then press
, the weight value will be
added into a sum memory
Ö „ACC 01“ will be shortly displayed, after that the system changes into the
standard weighing mode. Next to the weight display „M+“ appears
Ö Unload the system, the display returns to „0.0“
Ö 2. Place the weighing good, wait for stability display „STABLE“
Ö Press
anew
Ö „ACC 02“ is displayed, after that the total sum of the weighing procedures will be
displayed briefly before the system returns to weighing mode
Ö Carry out further weighings in the same way. Ensure that the system is unloaded
between the weighing procedures.
Ö The weighing system maximally can carry out 99 single weighing procedures
Ö To print out data unload weighing system and press
Printout example (see chap. 8 Printer):
Date 2011/07/04 Date
Time 14:03:26 Time
No.
3 Number of single weighings
N.W.
30.0kg Weight of the last single weighing
TOTAL 66.0kg Total
weight