beautypg.com

0 controller installation, 1 do, Proximity elevator control panel – Keri Systems LC-508 Proximity Elevator Control User Manual

Page 5

background image

Proximity Elevator Control Panel

2305 Bering Drive

01941-001 Rev. B

San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: www.kerisys.com E-mail: [email protected]

Page 5 of 22

LC-502P/LC-508P

Quick S

tart Guide

4.0

Controller Installation

Sections 4.1 and 4.2 are quick lists of things to do and to not do when installing LC-502P and LC-
508P panels.

4.1

Do

Plan ahead to meet power and telephone requirements for your system (1 phone line for the host
computer and one for each master LC-500P controller in each network).

Mount controllers in environmentally suitable areas – they require protection from weather and
from temperature/humidity extremes.

Mount the controller at least 3 feet away from the controller's power supply to prevent EMI
radiated from the power supply from affecting the controller.

Use isolation relays where needed.

Use the enclosure as a mounting template to mark drilling holes for permanent mounting.

Consider mounting requirements - central versus distributed.
-

Central mounting places all controllers in one location, running lengths of cables out to each
door to support readers, inputs and outputs.

-

Distributed mounting places each controller near the door it supports running short lengths
of cable out to each door, but running a long network communication cable.

Note the locations of the knockouts in the enclosures and remove the appropriate knockout for
the easiest cable routing into the controller.

Route all controllers in a network in a single, continuous daisy-chain.

Route cables in accessible areas for ease of maintenance.

Connect all controllers to a quality earth ground.

Add transient suppression across electric devices attached to a controller output.

Verify the controller's supply voltage is 12 VDC – long power line runs cause a drop in voltage
at the end of the run.

Verify proper operation of the host computer's COM port.

This manual is related to the following products: